Adjustments (cont.)
Brew Volume “br”
Brew time can be set for each size visually. See Setting Brew Volume Procedure below.
Brew time can also be adjusted through the display. See Programming Routine section.
Setting Brew Volume Visually
1.Remove brew basket and place container under brew head.
2.Press and hold desired brew button for 5 seconds. Display will read “Pro”.
3.Within 20 seconds, press and release desired brew button. Water will dispense from spray head and time will
4.When volume is at desired amount, press and release brew button to stop flow. Time will flash in display.
5.Within 20 seconds, press and release desired brew button. Display will clear and brew time will be stored into memory.
Note: During this routine, no pulsing or bypass will occur.
Note: If the On/Off button is pressed during procedure, time setting will default to previous time.
Control Features
Brew Countdown Timer: After the start of a brew the LED display will countdown the remaining time left in the brew process. The countdown will include all OFF periods programmed in the
Energy Savings Mode: If enabled, when the brewer is idle for three (3) hours this feature will allow the water tank to lower its holding temperature to 120°F. The display will scroll SLEEPIng while in this mode. To exit energy savings mode press any button and the unit will start reheating to brewing temperature.
Programming
On twin brewers, the right side, Large portion button gives the user access to the global programming parameters of the brewer, such as; Tank Temperature, Energy Savings Mode, Enable/Disable Low Temp No Brew, ON/OFF, Drip Time and Bypass Ratio. After the global parameters are set, the individual portion brew parameters can be set. All other portion sizes (left and right) only access individual brew parameters to that particular portion. Also, on twin brewers, the last program step in programming individual brew parameters allows the operator to copy those brew parameters to the left side if “YES” is selected. If “YES” is selected, the brew parameters that were set for the right side for that particular portion are copied to the left side. If “NO” is selected, then the left side must be programmed separately.
To enter program mode:
Press the UP and DOWN arrows simultaneously for 5 seconds. Once in program mode, the green LED for each por- tions size will flash.
Page 8 | Shuttle Brewers & Airpot/Shuttle Brewers |