Grindmaster APBIC-430V2 A530-066 Control Board, Troubleshooting cont, Brewing Problems, Remedy

Models: APB-430V2E230 APBIC-330V2E230 APB-430V2 APBIC-330V2 APBVSA-430V2E230 APB-330V2E230 APB-330V2 APBIC-430V2E230 APBVSA-430V2 APBIC-430V2 APBVSA-330V2 APBVSA-330V2E230

1 44
Download 44 pages 22.1 Kb
Page 26
Image 26
the Troubleshooting

Troubleshooting (cont.)

Brewing Problems

Problem

Possible Causes

Service Check

Remedy

 

 

 

 

Brew cycle will

• Controller faulty.

• Check to see that the

• If there is not 24 Vac across

not start

 

power is supplied to the

brew valve, replace control

 

 

controller by following

board.

 

 

instructions given in

 

 

 

the Troubleshooting

 

 

 

section on Filling

 

 

 

Problems. Once

 

 

 

touchpad and momentary

 

 

 

switch integrity is

 

 

 

assured (see above),

 

 

 

initiate a brew cycle

 

 

 

and check for 24 Vac

 

 

 

across brew valve.

 

 

 

 

 

Sprayhead will not

• Brew valve not closing

• Visually inspect brew

• Clean lime from valve. Seat,

stop dripping water

completely.

valve at hose

cup or entire valve may need

 

 

connections.

replacement.

 

• Water in tank boiling.

• Remove sprayhead

• Reduce tank temperature.

 

 

and determine if drip is

 

 

 

coming from overflow.

 

 

 

 

 

If you still need help, call our Service Department at (800) 695-4500 (USA and Canada only) or (502) 425-4776 (Monday-Friday 8:00 am - 6:00 pm EST) or an authorized service center in your area. Please have the model and serial number ready so that accurate information can be given.

Prior authorization must be obtained from Grindmaster-Cecilware’s Technical Services Department for all warranty claims.

A530-066 Control Board

used on all PrecisionBrew™ V2.0 models

Refers to software version number.

Subject to change.

Page 26

Shuttle Brewers & Airpot/Shuttle Brewers

Page 26
Image 26
Grindmaster APBIC-430V2 A530-066 Control Board, Troubleshooting cont, Brewing Problems, Possible Causes, Service Check