Programming (cont.)
To program the following items, press the Large, Right side portion button. (refer to Table 1)
1) | Temperature Scale: | Choose °F or °C |
2)Set Water Tank Temperature: Choose between 170°F - 205°F
3) | EnErGy mOdE: | Choose YES or NO |
4) | Ltn (Low Temp No Brew): | Choose YES or NO |
|
| • If YES, the brewer will only allow a brew to begin if the water tank |
|
| temperature is within 5°F of set point. |
|
| • If NO, the brewer will brew at any temperature. |
5) | DriP time: | Choose from 40% to 80% of brew time. |
|
| This is the amount of time the brewer takes to completely drain the brew |
|
| basket after the brew valve closes. The factory default is 50%, so if the |
|
| brewer is set for a 1.5 gallon brew, without |
|
| brew basket will remain locked for 2 minutes after the brew valve closes. |
|
| If, with coffee, the brew basket drips for longer than 2 minutes, increase |
|
| the setting to 60% which will be 2:24 of drip time. The setting increases by |
|
| 5% increments; 12 seconds each. |
6) | rto (Set Bypass Ratio): | Choose Std or Grm |
|
| • Choose Std if you are using the standard sprayhead. |
|
| • Choose Grm if you are using the gourmet sprayhead. |
Bypass ratio is the last global program parameter to be set. The following are the individual brew portion parameters. Each portion button can have individual brew sequences.
7) | Br time (Brew time): | Choose between 0:01 to 6:00 minutes. |
|
| This time setting controls the brew volume. The brewer brews at a rate of |
|
| 1.5 gallons in four minutes (48 ounces per minute / 0.8 ounces per second). |
|
| The Large portion button is factory set to brew 1.5 gallons or 4 minutes of |
|
| brew time. Adjust the brew volume to desired level. One second of brew |
|
| time will change brew volume by 0.8 ounces. |
8) | PrE inFuSion: | Choose OFF to 2:00 minutes. |
|
| This is the amount of |
|
| |
9) | PrE inFuSion oFF: | Choose 0.05 to 2:00 minutes. |
|
| This is the OFF time that allows the brew basket to drain the |
|
| volume of water. |
10) | PuLSE br: | Choose OFF to 10 |
|
| This will set the number of brew pulses desired. If none are desired, then |
|
| set to OFF. |
11) | PuLSE on (Pulse ON time): | Choose 0:05 - 2:00 minutes |
|
| If pulses are set to 10, program the ON time for the pulses. The same ON |
|
| time is used on all pulses. |
12) | PuLSE oFF (Pulse OFF time): | Choose 0:05 - 2:00 minutes |
|
| If pulses are set on step 10, then program the OFF time for the pulses. The |
|
| same OFF time is used on all pulses. |
Shuttle Brewers & Airpot/Shuttle Brewers | Page 9 |