Troubleshooting (cont.)

Brewing Problems

Problem

 

Possible Causes

Service Check

Remedy

 

 

 

 

 

 

Brew volume too

• Sprayhead clogged.

• Visually check for

• Clean all holes.

large or too small

 

 

clogging of holes

 

 

 

 

 

in brewhead.

 

 

 

• Brew valves clogged

• Visually inspect

• Clean lime from valve. Seat,

 

with lime deposits.

brew valve at

cup or entire valve may need

 

 

 

hose connections.

replacement.

 

• Water supply pressure

• Check to see that fill

• Supply water at adequate

 

or flow rate not

valve cycles on and

pressure and flow rate.

 

adequate.

off frequently during

 

 

 

 

 

brew cycle when all

 

 

 

 

 

brew heads are used

 

 

 

 

 

simultaneously. Check

 

 

 

 

 

to ensure that water

 

 

 

 

 

supply line is 3/8” and

 

 

 

 

 

pressure is between

 

 

 

 

 

30 and 80 psi (207 and

 

 

 

 

 

552 KPA).

 

 

 

 

 

 

 

 

Brew volume

• Water supply pressure

• Check water pressure

• Plumb water supply so that

erratic

fluctuates.

with and without other

water pressure is not

 

 

 

appliances operating.

significantly affected by

 

 

 

 

other appliances.

 

 

 

 

 

 

 

 

Note: Small variations from batch to batch are normal.

 

 

 

 

 

 

 

 

 

 

 

 

 

Brew cycle will

• Optional momentary

• Check to see that

• If fully engaged switch does

not start

switch to indicate

container fully engages

not complete circuit across

 

container in place not

switch. Check for

terminals of switch, replace

 

engaged or faulty.

continuity across switch

switch.

 

 

 

when switch is engaged.

 

 

 

• Brew circuit connections

• Check to see that

• Secure connections.

 

not secure.

connector (6-pin)

 

 

 

 

 

is securely connected to

 

 

 

 

 

control board. Check to

 

 

 

 

 

see that all connections

 

 

 

 

 

from controller through

 

 

 

 

 

brew valve are secure.

 

 

 

• Brew valve faulty.

• Check to see if there is

• If there is 24 Vac across

 

 

 

24 Vac across brew valve

terminals and brew valve is

 

 

 

terminals.

not open, replace valve.

 

• Touchpad faulty.

• Check to see that

• If connections are secure,

 

 

 

touchpad connections

other functions appear normal

 

 

 

to control board are

and touchpad will not initiate a

 

 

 

secure.

brew cycle, replace touchpad.

 

 

 

 

 

 

 

 

 

 

 

 