SECTION 2: CIRCUIT REQUIREMENTS
Serious personal injury could occur if you connect the machine to the power source before you have completed the setup pro- cess. DO NOT connect the machine to the power source until instructed to do so.
Full Load Amperage Draw
G0460 5 HP 220V | 22 Amps |
G0461 7.5 HP 220V | 20 Amps |
G0461 7.5 HP 440V | 10 Amps |
Circuit Requirements
We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a qualified electri- cian to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.
G0460 220V | 30 Amp |
G0461 220V | 30 Amp |
G0461 440V | 15 Amp |
Minimum Cord Requirements
For 220V connection, we recommend using a
G0460 220V | ...........10/3 AWG, 300VAC |
G0461 220V | ...........10/4 AWG, 300VAC |
G0461 440V | ...... Electrician to Hardwire |
220V Plug/Connection Type |
G0460 220V |
G0461 220V |
Figure 4. NEMA L6-30 plug and receptacle.
Figure 5. NEMA L15-30 plug and receptacle.
G0461 440V Connection to Power
Have a qualified electrician hardwire this machine to a dedicated locking
������� | ������� | |
�� | ||
�� | ||
������� | ||
������������ | ||
|