SECTION 2: CIRCUIT REQUIREMENTS

Serious personal injury could occur if you connect the machine to the power source before you have completed the setup pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Full Load Amperage Draw

G0460 5 HP 220V 1-Phase

22 Amps

G0461 7.5 HP 220V 3-Phase

20 Amps

G0461 7.5 HP 440V 3-Phase

10 Amps

Circuit Requirements

We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a qualified electri- cian to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

G0460 220V 1-Phase

30 Amp

G0461 220V 3-Phase

30 Amp

G0461 440V 3-Phase

15 Amp

Minimum Cord Requirements

For 220V connection, we recommend using a stranded-copper flexible cord that meets the minimum criteria listed below, does not exceed 50 ft., and has an insulation type that starts with "S." The exact insulation type should account for any exposure to moisture, heat, and oils in the working environment.

G0460 220V 1-Phase

...........10/3 AWG, 300VAC

G0461 220V 3-Phase

...........10/4 AWG, 300VAC

G0461 440V 3-Phase

...... Electrician to Hardwire

-12-

220V Plug/Connection Type

G0460 220V 1-Phase.................................L6-30

G0461 220V 3-Phase............................... L15-30

Figure 4. NEMA L6-30 plug and receptacle.

Figure 5. NEMA L15-30 plug and receptacle.

G0461 440V Connection to Power

Have a qualified electrician hardwire this machine to a dedicated locking shut-off switch that is con- nected to the main power source.

�������

�������

��

��

�������

������������

 

Figure 6. Hardwired locking disconnect switch.

G0460/G0461 12" Sliding Table Saw

Page 14
Image 14
Grizzly G0460/G0461 owner manual Circuit Requirements