Air Filter Indicator

To install the air filter indicator:

1.Mount the manometer to the side of the spray booth by threading the M4 x 45 tap screws into the pre-drilled holes (Figure 15).

Built-in

Level

Figure 15. Mounting manometer to spray booth.

2.Adjust the manometer so the built-in level reads level (Figure 15).

3.Install a tubing connector fitting in the larger pre-drilled hole on the side of the booth near the manometer as shown in Figure 16.

Model G0533 (Mfg. Since 3/11)

Tubing

Connector

Fitting

Figure 16. Tubing installed onto spray booth

chamber.

4.Run tubing from the low pressure side (-) of the manometer to the tubing connector fitting as shown in Figure 16.

5.Install tubing into the high pressure side (+) of the manometer and secure it with the plastic clip and an M4 x 12 tap screw as shown in

Figure 17.

Plastic

Clip

Figure 17. Tubing secured with clip.

-17-

Page 19
Image 19