SECTION 2: CIRCUIT REQUIREMENTS

220V Operation

 

Circuit Load

 

 

 

 

 

 

The Model G8030 has a 3 H.P., 3450 R.P.M. motor which requires a 220V single-phase circuit. The cord set enclosed does not have a plug as the style of plug you require will depend upon the type of service you currently have or plan to install. The motor will safely draw about 15 amps at 220V under load. If you operate the Model G8030 on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist, and power failure still occurs, have the cir- cuit inspected by a qualified electrician.

When operating at 220V, we recommend using a NEMA-style 6L-20 plug and outlet. See Figure 1. You may also “hard-wire” the machine directly to your panel, provided you place a disconnect switch near the machine. Check the electrical codes in your area for specifics on wiring require- ments.

Under normal use, the motor draws approximate- ly 15 amps at 220V. We recommend a 20 amp cir- cuit breaker for 220V operation. This should be satisfactory for normal use while providing enough protection against circuit damage caused by power surges.

Figure 1. Typical 220V 3-prong plug and outlet

 

 

 

 

 

 

 

 

G8030 3 H.P. Overarm Router

 

 

-5-

Page 7
Image 7