13.Air Flow Support Instructions

13.Air Flow Support Instructions

*Installation, Spacing and Quantities of Air Flow Supports Under Channel Lock Floors

Bin Diameter - Number of Supports

Grain

 

 

18 Ft. Dia.

 

 

21 Ft. Dia.

 

 

24 Ft. Dia.

 

27 Ft. Dia.

 

 

30 Ft. Dia.

 

Depth at

Spacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Wall

(in.)

Full

Double

 

Single

Full

Double

 

Single

Full

Double

Single

Full

Double

 

Single

Full

Double

 

Single

(ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

30"

34

2

 

8

48

2

 

10

60

2

12

84

2

 

14

88

2

 

14

24'

26"

36

2

 

8

56

2

 

10

74

2

12

92

2

 

14

104

2

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27'

24"

44

2

 

8

62

2

 

10

76

2

12

92

2

 

14

112

2

 

14

32'

20"

54

2

 

10

64

2

 

12

84

2

14

106

2

 

16

130

2

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40'

16"

58

10

 

14

80

12

 

16

104

14

18

128

16

 

20

160

18

 

22

48'

13"

72

10

 

16

98

12

 

20

126

14

22

158

16

 

24

190

18

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53'

12"

76

10

 

18

106

12

 

22

140

14

24

172

16

 

28

210

18

 

30

68'

10"

86

10

 

22

116

12

 

26

156

14

28

212

16

 

32

250

18

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16'

24" and 12"

68

10

 

8

82

12

 

10

104

14

12

120

16

 

14

140

18

 

14

(for Grain Flow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Diameter - Number of Supports

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grain

 

 

33 Ft. Dia.

 

 

36 Ft. Dia.

 

 

42 Ft. Dia.

 

48 Ft. Dia.

 

 

60 Ft. Dia.

 

Depth at

Spacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Wall

(in.)

Full

Double

 

Single

Full

Double

 

Single

Full

Double

Single

Full

Double

 

Single

Full

Double

 

Single

(ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

30"

116

2

 

16

136

2

 

18

172

2

20

Use 24" Spacing

Use 24" Spacing

24'

26"

124

2

 

16

144

2

 

18

200

2

20

Use 24" Spacing

Use 24" Spacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27'

24"

136

2

 

16

154

2

 

18

212

2

20

274

2

 

22

422

2

 

30

32'

20"

150

2

 

20

184

2

 

22

242

2

26

326

2

 

28

498

2

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40'

16"

192

20

 

24

234

22

 

28

314

24

32

410

28

 

36

620

34

 

46

48'

13"

238

20

 

30

278

22

 

34

368

24

38

488

28

 

44

762

34

 

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53'

12"

262

20

 

34

306

22

 

36

416

24

42

534

28

 

48

838

34

 

60

68'

10"

296

20

 

40

356

22

 

44

478

24

50

652

28

 

58

1024

34

 

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16'

24" and 12"

168

20

 

16

188

20

 

18

264

24

20

350

28

 

20

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(for Grain Flow)

Notes:

1.Use a maximum spacing of 16" for perforated corrugated flooring.

2.The number of supports listed is based on the maximum peaked capacity of each bin.

3.Use extra single supports for split floors.

4.Extra supports are required for grain recirculating equipment. Use the manufacturer’s recommendation for the number and spacing of extra supports. NOTE: For grain flows, air flow supports are doubled in a 14' diameter in the center of the floor.

5.Contact a representative for air flow supports required for larger bins and deeper grain depths.

6.* Increase the number of supports by 5% when used with 6-3/4" wide mfs floor planks.