GSI Outdoors PNEG-214 Lock Floors York and Chief Bins, Air Flow Support Instructions

Models: PNEG-214

1 38
Download 38 pages 4.25 Kb
Page 34
Image 34
Lock Floors York and Chief Bins

13. Air Flow Support Instructions

Installation, Spacing and Quantities of Air Flow Supports Under Channel

Lock Floors York and Chief Bins

Bin Diameter - Number of Supports

 

Grain

 

 

15' 6"

 

 

 

 

 

18' 7"

 

 

21' 8"

 

 

24' 9"

 

 

 

27' 10"

 

 

 

 

Depth at

Spacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Wall

(in.)

Full

Double

 

Single

 

Full

 

Double

Single

Full

Double

Single

Full

Double

 

Single

Full

Double

 

Single

 

 

(ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

30"

26

2

 

8

 

36

2

8

50

2

10

64

2

12

80

2

 

14

 

 

24'

26"

30

2

 

8

 

42

2

8

56

2

10

74

2

12

92

2

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27'

24"

32

2

 

8

 

44

2

8

60

2

10

78

2

12

98

2

 

14

 

 

32'

20"

38

2

 

10

 

52

2

10

72

2

12

92

2

14

116

2

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40'

16"

46

10

 

14

 

64

12

14

86

14

16

114

14

18

142

16

 

20

 

 

48'

13"

54

10

 

16

 

78

12

16

106

14

20

136

14

22

172

16

 

24

 

 

53'

12"

58

10

 

18

 

84

12

18

114

14

22

148

14

24

184

16

 

28

 

 

68'

10"

70

10

 

22

 

98

12

22

134

14

26

174

14

28

220

16

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16'

24" and 12"

60

10

 

8

 

72

12

8

88

14

10

106

14

12

126

16

 

14

 

 

(for Grain Flow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Diameter - Number of Supports

 

 

 

 

 

 

 

 

 

 

 

 

Grain

 

 

31'

 

 

 

 

 

34'

 

 

37' 1"

 

 

40' 3"

 

 

 

43' 4"

 

 

 

 

Depth at

Spacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Wall

(in.)

Full

Double

 

Single

Full

 

Double

Single

Full

Double

Single

Full

Double

 

Single

Full

 

Double

Single

 

 

(ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

30"

98

2

 

14

 

116

2

16

136

2

18

160

2

20

182

2

 

22

 

 

24'

26"

112

2

 

14

 

132

2

16

154

2

18

182

2

20

208

2

 

22

 

 

27'

24"

120

2

 

14

 

142

2

16

166

2

18

196

2

20

224

2

 

22

 

 

32'

20"

140

2

 

18

 

168

2

20

198

2

22

232

2

26

260

2

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40'

16"

174

18

 

22

 

208

20

24

244

22

28

286

24

32

330

26

 

32

 

 

48'

13"

210

18

 

28

 

252

20

30

298

22

34

350

24

38

402

26

 

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53'

12"

228

18

 

30

 

272

20

34

316

22

36

378

24

42

434

26

 

42

 

 

68'

10"

270

18

 

36

 

324

20

40

384

22

44

450

24

50

520

26

 

50

 

 

16'

24" and 12"

148

18

 

14

 

170

20

16

194

22

18

224

24

20

252

26

 

22

 

(for Grain Flow)

Bin Diameter - Number of Supports

Grain

 

 

49' 6"

 

 

55' 8"

 

 

61' 10"

 

Depth at

Spacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Wall

(in.)

Full

Double

Single

Full

Double

Single

Full

Double

Single

(ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

24"

288

2

28

362

2

32

444

2

36

24'

20"

346

2

28

436

2

32

536

2

36

 

 

 

 

 

 

 

 

 

 

 

27'

20"

346

2

28

436

2

32

536

2

36

32'

20"

346

2

28

436

2

32

536

2

36

40'

16"

428

28

36

540

32

42

664

36

46

48'

13"

524

28

44

660

32

52

812

36

56

 

 

 

 

 

 

 

 

 

 

 

53'

12"

566

28

48

714

32

54

878

36

60

68'

10"

676

28

58

852

32

68

1050

36

72

34

PNEG-21412'-18 Cor-Lok and Cut-Lok Flooring

Page 34
Image 34
GSI Outdoors PNEG-214 installation manual Lock Floors York and Chief Bins, Air Flow Support Instructions