Haier AE122BCAAA (H2EM-18H03) manual Troubleshooting, Symptom, Cause

Models: AE122BCAAA (H2EM-18H03)

1 27
Download 27 pages 7.05 Kb
Page 14
Image 14
 Troubleshooting

Symptom Troubleshooting

Before as the special repair center for help, please check the following items of the air conditioner

Not trouble

Symptom

Hear the sound of water flow

In DEHUMIDIFYING, no air sent out or cannot change the fan speed.

Having peculiar smell in the out air

The stopped indoor unit gives out sound, white vapor or cold air.

Cause

The water flow sound when operation starts; during operation and shortly after operation stops, in 2-3 minutes shortly after the operation starts, sometimes the sound becomes louder. This is the sound of refrigerant flow and the draining sound of condensate water.

In DEHUMIDIFYING operation, when the room temperature is 2 CauseC higher than the set temperature, despite of the set FAN SPEED the air conditioner will operate in LOW FAN SPEED.

Because the smells generated by wall, carpet, furniture,clothes, cigarette and cosmetic, etc. attached on the air conditioner.

In order to prevent the oil and refrigerant from resorting in the indoor unit, there is refrigerant flow in very short time, so they give out ìSha, Shaî, ìGulu, Guluî. Additionally, when the other indoor units perform HEATING operation, sometimes white vapor appears; when the other indoor units perform COOLING operation, cold air appears.

If there is the following symptom and check they are the following causes, please solve them according to the below given methods.

Symptom

The unit does not work

Once the unit starts, it stops immediately

Abnormal COOLING or

HEATING

Causes

The fuse is blown out or the breaker is open-circuit.

The air inlet or outlet of indoor and outdoor unit is blocked

The air inlet or outlet of indoor and outdoor unit is blocked

Improper set temperature The fan speed is set too low Doors or windows are open

Direct sunshine. (COOLING) Too much people in room (COOLING) Toomanyheatsourcesinroom(COOLING)

Solution

Change fuse or close breaker

Remove the obstacle

Remove the obstacle

Refer to page 7

Refer to page 7

Close them

Hang curtains or blinds before window

Trouble Contents

Code Displayed

Indoor temperature sensor trouble

F1

 

 

Inner pipe coil sensor trouble (thin pipe)

F2

 

 

Inner pipe coil sensor trouble (thick pipe)

F4

 

 

High pressure trouble (pressure)

F5

Drainage trouble

F6

 

 

If after the above checking and treatment, the air conditioner still cannot work normally, or

 

find the following phenomena, please stop the unit and contact the commissioned service

 

center.

 

The fuse or breaker is often blown out or open circuit.

 

In COOLING or DEHUMIDIFYING, there is water leakage.

 

Abnormal operation or abnormal sound be heard.

 

The display screen of the wire controller shows trouble code indicating the unit has

13

trouble.