Haier AE122BCAAA (H2EM-18H03) manual Installation procedure Install indoor unit

Models: AE122BCAAA (H2EM-18H03)

1 27
Download 27 pages 7.05 Kb
Page 23
Image 23
Permitted length and fall of connecting pipe

Material and dimension of connecting pipeInstallation procedure Install indoor unit

!warning

Connection of refrigerant pipe During installation, if refrigerant leakage occurs, please immediately take ventilation measure. If the refrigerant gas meet the fire, it may generate poisonous gas.

Manual background After finishing installation work, please make sure there is no refrigerant leakage. If the leaked refrigerant gas meet heater and oven, etc. fire sources, it may generate poisonous gas.

Permitted length and fall of connecting pipe

Depending on the outdoor units, for details, please refer to the attahed manual of outdoor unit.

Material and dimension of connecting pipe

Material of connecting pipe

Phospor deoxy copper seamless pipe used in air conditioner (TP2)

Dimension of connecting pipe

Gas side

12.7

( mm )

Liquid side

6.35

Connection of refrigerant pipe

Two spanners operation

Perform connection of flared pipe to connect all the refrigerant pipes.

Manual background The connection of indoor unit connecting pipe must be performed by two spanners.

Manual background For installation torque, please refer to the following table.

External diameter of conneting pipe(mm)

Manual background 6.35

Manual background 12.7

Installation torque (N.m)

Tightening torque (N.m)

11.8(1.2kgf.m)

13.7(1.4kgf.m)

49.05(5.0kgf.m)

53.9(5.5kgf.m)

 

 

22

Page 23
Image 23
Haier AE122BCAAA (H2EM-18H03) Installation procedure Install indoor unit, Permitted length and fall of connecting pipe