Haier AE122BCAAA (H2EM-18H03) manual Installation procedure Install indoor unit, Indoor unit

Models: AE122BCAAA (H2EM-18H03)

1 27
Download 27 pages 7.05 Kb
Page 18
Image 18
Installation procedure Install indoor unit

Indoor unitInstallation procedure Install indoor unit

! Notice

Safety precautions Do not install the air conditioner at the place where the combustible gas maybe leak. In case of the leaked gas gather around the unit, it may cause fire accident.

The indoor unit should be installed in the place where the cool air and warm air may evenly circulate.

Avoid the following places:

Manual background Place with too much salinity (coastal area).

Manual background Place with too much sulfuration gas (mainly is the hotspring area, the copper pipe and brazed part are easily corroded).

Manual background Place with too much oil (including mechanical oil) and vapor.

Manual background Place using organic solvent.

Manual background Place with machines may generate high frequency electromagnetic waves. (The control system may have abnormality)

Manual background Place near the doors or windows that come close to the external high humidity air. (may easily form dew)

Manual background Place where the special sprayer may be frequently used.

Manual background On vehicles, boats and ships.

Manual background Place less than 1m away from TV, radio, radio devices and fluorescent lamp.

Indoor unit

1.Choose the place where the air from the air conditioner can spread throughout the room and where the connection pipe, connection wire and drain hose may be easily arranged to the suitable outdoor position.

2.Choose the place where the vertical distance between the center of air outlet and the ground is no more than 2.7m.

3.The structure of the ceiling should be firm enough to bear the weight of the unit.

4.The connection pipe, drain hose and connection wire can penetrate

through the wall and connect indoor and outdoor unit.

5.The connection pipe and drain hose between indoor and outdoor unit should be as short as possible.

6.The connection flare should be provided by user.

Safety precautions

1.For those models with electric heat function, it is forbidden to directly connect the air outlet with canvas and material alike inflammable interfaces.

2.When installing indoor unit, it is necessary to leave a checking hole for convenient repair.

17

Page 18
Image 18
Haier AE122BCAAA (H2EM-18H03) manual Installation procedure Install indoor unit, Indoor unit, Safety precautions