Haier AP602AKEAA, AP482AKEAA installation manual Installation procedures Electric wiring

Models: AP482AKEAA AP602AKEAA

1 30
Download 30 pages 38.4 Kb
Page 28
Image 28
 Installation procedures Electric wiring

Manual background Installation procedures Electric wiring

Note:

Manual background Electric wiring must be done by qualified person.

Manual background The power supply connects from the outdoor unit.

Manual background The connecting cable and power cable are self-provided.

Wiring of indoor unit

Manual background Insert the cable from outside the wall hole where piping already exist.

Manual background Pull it out from front.

Manual background Loosen terminal screws and insert cable end fully into terminal block, then tighten it.

Pull the cable gently to make sure it is tight.

 

Replace cover after wiring.

OK

NO

Wiring of outdoor unit

 

terminal block

 

 

Insert the cable from inside the wall

hole

table clamp

where piping already exists.

 

 

 

Pull it out from front.

 

 

Manual background Loose terminal screw and insert cable end fully into terminal block, then tighten it.

Manual background Pull the cable gently to make sure it is tight. Manual background Replace cover after wiring.

AP482AKEAA AP602AKEAA

1 2 3 Manual backgroundManual backgroundManual background

Y/G

Y/GManual backgroundManual backgroundR Manual background S Manual background T N Manual background 1 2 3 Manual backgroundManual backgroundManual background

POWER SUPPLY: 380-400V, 3N~, 50Hz

Note:

When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks.Incorrect wiring may damage air conditioner's controller or cause operation failure.

26

Page 28
Image 28