Haier AP482AKEAA, AP602AKEAA Others, Flaring tool, Correct, Incorrect, Lean Damaged flare Crack

Models: AP482AKEAA AP602AKEAA

1 30
Download 30 pages 38.4 Kb
Page 29
Image 29
 Others

Correct Others

1. Pipe cutting and flaring

Incorrect Be sure to carry out deburring after pipe cutting with a pipe cutter. Lean Damaged flare Crack Insert flaring tool to make a flare.

Correct

Incorrect

Lean Damaged flare Crack

Partial Too outside

 

Pipe dia.

Dimension A(mm)

 

 

 

Liquid pipe

9.52mm (3/8")

1.0 ~ 1.8

 

 

 

Gas pipe

19.05mm (3/4")

1.4 ~ 2.2

 

 

 

A

Flaring tool

2.Installation inspection and test run:

Please operate unit according to this Manual.

Items to be checked during test run. Please made a "Partial Too outside" in "Flaring tool"

Manual backgroundManual background Are there any gas leakage?

Manual backgroundManual background How is insulation at piping connection carried out?

Manual backgroundManual background Are electric wires of indoor and outdoor unit firmly inserted into terminal block?

Manual backgroundManual background Is electric wiring of indoor and outdoor securely fixed?

Manual backgroundManual background Is draminage securely carried out?

Manual backgroundManual background Is earth line ( grounding ) securely connected?

Manual backgroundManual background Is power supply voltage abided by the code?

Manual backgroundManual background Is there any noise?

Manual backgroundManual background Is control display normal?

Manual backgroundManual background Is cooling operation normal?

Manual backgroundManual background Is room temp. regulator normal?