Haier AP482AKEAA Installation procedures, Indoor unit, Slope, Good, Down, Purging method

Models: AP482AKEAA AP602AKEAA

1 30
Download 30 pages 38.4 Kb
Page 27
Image 27
Indoor unit

Slope Installation procedures

Arrangement of drain hose

Good Drain hose shall be placed in under place.

Down There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.

Indoor unit

 

 

Up

 

Slope

Good

Down

Bad

 

If humidity is high, drain pipe( especially in room and indoor unit ) must be covered with insulation material.

3.Piping connection of outdoor unit.

Connect the connecting pipe and inlet and outlet liquid pipe according to the piping method.

4.Purging method

Discharge the air out of the indoor unit and the refrigerant pipe by vacuumizing

(1)Fasten all the nuts of the indoor and outdoor pipes to make these parts out of leakage.

(2)Under the condition of the complete close of the indoor and outdoor valve center (both liquid and gas side),dismount the repair valve cap.Vacuumizing through the charge mouth of the repair valve.

(3)After vacuumizing fasten the repair valve,and dismount the cap of the big and small stop valve, then loosen the stop valve center completely and fasten the big and small stop valve.

25

Page 27
Image 27
Haier AP482AKEAA, AP602AKEAA Installation procedures, Indoor unit, Slope, Good, Down, Piping connection of outdoor unit