Failure code

 

FAILURE CODE

 

 

TROUBLE SHOOTING

(TIMER LED OF INDOOR

POSSIBLE REASONS

RECEIVER BOARD FLASHES

 

TIMES)

 

 

 

 

 

 

Faulty temperature sensor Tai

ONCE

Sensor disconnected, or broken, or at wrong

position, or short circuit

 

 

 

 

 

Faulty temperature sensor Tc1

TWICE

Sensor disconnected, or broken, or at wrong

 

position, or short circuit

 

 

 

Faulty temperature sensor Tc2

3 TIMES

Sensor disconnected, or broken, or at wrong

position, or short circuit

 

 

Faulty temperature sensor Tm

4 TIMES

Sensor disconnected, or broken, or at wrong

 

position, or short circuit

 

 

 

Faulty EEPROM on indoor

5 TIMES

Faulty indoor unit PCB

unit PCB

 

 

 

Abnormal communication

 

Wrong connection, or the wires be disconnected,

6 TIMES

or wrong address setting of indoor units, or faulty

between indoor and outdoor unit

 

PCB, or faulty power supply

 

 

 

 

 

 

Indoor unit address repeated

9 TIMES

Wrong setting of indoor unit address

 

 

 

 

Central control address repeated

10 TIMES

Wrong setting of centralized control indoor unit

address

 

 

 

 

 

 

Faulty indoor unit fan motor

11 TIMES

Fan is blocked, or the terminal is disconnected

from the PCB, or faulty indoor unit PCB

 

 

 

 

 

 

Faulty driver of indoor unit

12 TIMES

Faulty indoor unit PCB

fan motor

 

 

 

 

 

 

 

Malfunction on outdoor unit

20 TIMES

Check the outdoor unit

 

 

 

 

Note:

1.Please contact the installers or distributors when trouble happens to repair it.

2.Turn the power off and power on again, if the failure code recurs, please change the indoor unit PCB.

3.Failrue codes maked with are resumable.

30