Haier AS072XHERA Specifications, Cautions, The machine is adaptive in following situation

Models: AS092XHERA AS072XHERA AS122XHERA

1 33
Download 33 pages 6.23 Kb
Page 4
Image 4
Specifications

The machine is adaptive in following situation Cautions

Manual background All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Manual background Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Manual background Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Manual background Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

 

DB C

35

43

10

 

outdoor

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

WB C

14.5

--

--

 

 

outdoor

DB C

7

24

-15

 

 

WB C

6

18

--

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken, please change it with the type of T 3.15A /250VAC

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable are self-provided.

The requirement of the connecting cable:

Model

Connecting cable(sheilded wire)

AS072XHERA

H05RN-F 3G 2.5mm2

AS092XHERA

H05RN-F 2X1.5mm2

AS122XHERA

 

 

 

All the cables shall have got the Local authentication certificate.

6.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less than 3mm. Such means for disconnection must be incorporation in the fixed wiring.

7.The waste battery shall be disposed properly.

8.The indoor unit installation height is at least 2m.

9.The appliance is not intended for ase young children or infirm persons without super vision.

10.Young children should be super vised to ensure that they do not play with the applience.

2