Emergency operation and test operation

Operation

Emergency operation and test operation

Emergency

Emergency Carry out this operation only when the remote controller is defective or lost.

Test operation: When the emergency operation switch is pressed, a " Pi " sound starts once, which

Removal of the restriction of emergency or test means the start of this operation.

In this operation, it is not possible to change the settings of temperature and air flow speed, it is Manual background also impossible to do an operation by the timer.

Room

Designated

Timer

Air

Operatio

temperature

temperatur

 

mode

flow

n mode

 

 

 

 

 

 

 

More than 23oC

26oC

 

 

 

AUT

COOL

 

 

 

 

 

 

 

 

 

 

Less than 23oC

23oC

 

 

 

AUT

HEA

 

 

 

 

 

 

 

 

 

 

Manual background If an air conditioner is a model for both cooling and heating.

Cooling when the room temperature at the start of operation is above 23oC. Heating when the room temperature at the start of operation is less 23oC.

Test operation:

Manual background Use this switch in the test operation when the room temperature is less 16oC, do not use it in the normal operation.

Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch, the cooling operation starts with the air flow speed setting "Hi".

Removal of the restriction of emergency or test

Manual background Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed.

Manual background When the remote controller is manipulated for the removal, then the selected operation by the remote controller.