Haier HBU-18HF03 Specifications, Cautions, The machine is adaptive in following situation

Models: HBU-18CF03 HBU-18HF03

1 25
Download 25 pages 3 Kb
Page 4
Image 4
Specifications

The machine is adaptive in following situation Cautions

Manual background All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.

Manual background Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Manual background Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Manual background Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

 

DB C

35

43

10

 

outdoor

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

WB C

14.5

--

--

 

 

 

outdoor

DB C

7

24

-7

 

 

WB C

6

18

--

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable are self-provided. The requirement of the power cable:

Model

 

HBU-18CF03

H07RN-F

HBU-18HF03

3G 2.5mm2

 

 

 

The requirement of the connecting cable: H07RN-3G2.0mm2+2*0.75mm2.(ForHBU-18HF03);

H07RN-F3G2.0mm2.(ForHBU-18CF03)

6.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring.

7.The waste battery shall be disposed properly.

8.The indoor unit installation height is at least 2.5m.

2

Page 4
Image 4
Haier HBU-18HF03, HBU-18CF03 operation manual Specifications, Cautions, The machine is adaptive in following situation