Operation
Base Operation
Remote controller
1 4
2
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is |
| operation | |||||
pressed,the" Pi "sound is heard once, which |
| ||||||
means the start of this operation. |
|
|
| emergency | |||
|
|
| Pi | ||||
|
|
|
|
|
| switch | |
In this operation, the system automatically selects |
| ||||||
the operation modes,cooling or fan or heat, |
|
| |||||
according to the room temperature. |
|
|
| ||||
| . |
|
|
|
|
| |
Room | Operation Designated | Timer | Air flow | ||||
temperature | mode | temperature | mode | ||||
|
| ||||||
ABOVE 24OC | COOLING | 24OC |
| NO | AUTOMATIC | ||
BELOW 24OC | HEAT | 24OC |
| NO | AUTOMATIC | ||
(Cooling only uint) | Operation | Designated | Timer | Air flow | |||
Room temperature | mode | temperature | mode | ||||
BELOW 24OC | FAN |
| 24OC | NO | AUTOMATIC |
It is not possible to operate in dry mode.
Remote controller:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUTO |
| COOL DRY FAN HEAT |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
3.Select temp.setting | ||||||||||||||
Press | / |
|
|
| button | |||||||||
| Every time the button is pressed, temp.setting | |||||||||||||
| increase 1oC,if kept depressed, it will increase | |||||||||||||
| rapidly |
|
|
|
|
|
|
|
|
|
| |||
| Every time the button is pressed, temp.setting | |||||||||||||
| decrease 1oC,if kept depressed, it will | |||||||||||||
| decrease | rapidly |
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16oC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
test operation switch
Pi
Pi
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW MED | HI | AUTO |
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation | Remote | Note |
|
Mode | Controller |
| |
|
| ||
|
| Under the mode of auto operation, air conditioner |
|
AUTO |
| will automatically select Cool or Heat operation |
|
| according to room temperature. When FAN is set |
| |
|
| to AUTO, the air conditioner automatically adjusts |
|
|
| the fan speed according to room temperature. |
|
COOL |
|
|
|
|
|
|
|
|
| In DRY mode, when room temperature becomes |
|
DRY |
| lower than temp.setting+2oC, unit will run |
|
| intermittently at LOW speed regardless of FAN |
| |
|
| setting. |
|
|
|
|
|
|
| In FAN operation mode , the unit will not operate in |
|
FAN |
| COOL or HEAT mode but only in FAN mode , |
|
| AUTO is not available in FAN mode. And temp. |
| |
|
| setting is disabled. In FAN mode, sleep operation |
|
|
| is not available. |
|
HEAT
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1 Pos.2 Pos.3
Pos.4 Pos.5 Pos.6 (Auto swing)
2.Left and right air flow adjustment
For each press of |
| button, remote controller | |
displays as follows : |
|
| |
remote controller: |
|
| |
Pos.1 | Pos.2 | Pos.3 | Pos.4 |
Pos.5 | Pos.6 | Pos.7 | Pos.8 |
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
3