Operation

Sleep Operation

Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.

Use of SLEEP function

After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.

Operation Mode

1. In COOL,DRY mode

1 hours after SLEEP mode starts,temp.will become

1OC higher than temp.setting.After another 1 hours, temp.rises by 1OC futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.

SLEEP operation starts

SLEEP operation stops

 

 

Approx.6hrs

 

1 hr

Rises 1OC

1 hr

Rises 1OC

 

 

Temp.setting

 

Unit stop

In COOL, DRY mode

2. In HEAT mode

1 hours after SLEEP mode starts,temp will become 2OC lower than temp.setting.After another 1 hours,temp decrease by 2OC futher.After more another 3hours,temp.rises by 1OC futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.

Temp.setting

 

Unit stop

1 hr

Decreases 2OC

 

 

1 hr

Decreases 2OC

 

 

 

 

 

3 hrs

 

 

3 hrs

Rises 1OC

SLEEP

 

 

SLEEP

 

 

 

operation stops

operation starts In HEAT mode

3. In AUTO mode

The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.

4. In FAN mode

It has no SLEEP function.

5.Set the wind speed change when sleeping

If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping.

If it is low wind, no change.

Note

When TIMER function is set, the sleeping function can't be set up .After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled;the machine will be in the state of timing-on.

POWER/SOFT Operation

(1)POWER Operation

When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode.

(2)SOFT Operation

You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed

automatically takes low speed of AUTO fan mode.

Note

During POWER operation, in rapid HEAT or COOL mode , the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.

To cancel POWER or SOFT operation

Press POWER/SOFT button again ,POWER or SOFT disappears.

Nano-Aquo Operation

Nano-Aquo generator adopt high voltage two poles to ionization the water moleculeproduce plenty of positive and negative Ionsand realease these inos to the air to kill the bacterium.And meantimebecause the negative ions qty more than positive ions qtythe Nano-Aquo generator also have the Negative ions generator function which can refresh the air.