Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
1OC higher than temp.setting.After another 1 hours, temp.rises by 1OC futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.
SLEEP operation starts | SLEEP operation stops |
|
| Approx.6hrs |
| 1 hr | Rises 1OC |
1 hr | Rises 1OC | |
|
| |
Temp.setting |
| Unit stop |
In COOL, DRY mode
2. In HEAT mode
1 hours after SLEEP mode starts,temp will become 2OC lower than temp.setting.After another 1 hours,temp decrease by 2OC futher.After more another 3hours,temp.rises by 1OC futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
Temp.setting |
| Unit stop | |
1 hr | Decreases 2OC |
| |
| 1 hr | Decreases 2OC | |
|
| ||
|
|
| 3 hrs |
|
| 3 hrs | Rises 1OC |
SLEEP |
|
| SLEEP |
|
|
| operation stops |
operation starts In HEAT mode |
3. In AUTO mode
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
Note
When TIMER function is set, the sleeping function can't be set up .After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled;the machine will be in the state of
POWER/SOFT Operation
(1)POWER Operation
When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode.
(2)SOFT Operation
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed
automatically takes low speed of AUTO fan mode.
Note :
During POWER operation, in rapid HEAT or COOL mode , the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again ,POWER or SOFT disappears.
Nano-Aquo Operation
4