Hampton Direct H200 installation manual Front Door Gasket, Handle

Models: H200

1 32
Download 32 pages 21.75 Kb
Page 25
Image 25

MAINTENANCE

FRONT DOOR GASKET

Front Door Handle Shown

If position of bracketry needs to be changed after adjustment:

If the front door gasket requires replacement 5/8" diameter material must be used. Hampton uses a 5/8" diameter gasket (Part# 936-232). A proper high temperature gasket adhesive is required. See your Hampton Dealer.

The bracketryshouldstartfromthehighest point, as seen below. If needed, bring the bracketry down 1/16" each time, until fi nding the best locking position. The door latch will catch best in this way.

(Listen for a double click sound when the door is locked).

 

Secure using 7/16"

 

socket wrench.

HANDLE

LATCH ADJUSTMENT

REPLACEMENT

METHOD

Bracketry at

highest position

1)Remove handle (front or side) by undoing the hex head bolt using a 7/16" socket wrench.

2)Fit new door handle over latch and se- cure.

Assembly shown below.

Spacer

Handle

Hex Head

LockBolt

Washer

The door bracketry may require adjustment as the door gasket material compresses after a few

res. Removal of the spacer washer will allow the latch to be moved closer to the door frame, causing a tighter seal.

Relocate the washer removed from the back of the bracket to the front. This will allow the same screw to be used.

Use the 3/16" allen key enclosed in the packaged manual to make this adjustment.

Front of Bracket

Remove spacer washers

behind screws.

Allen Key

Front of

Bracket

Hampton H200 Cast Freestanding Woodstove

25

Page 25
Image 25