In rare instances where neither a valid Start nor Stop pattern is measurable, yet the symbol is somehow read, lines {8} and {9} are replaced by a message to that effect. The message is either:
"[F] < Start/Stop Decode Fails" in a Full Report or "Start/Stop Characters are Bad" in a Screening mode.
In Screening modes, it often occurs that none of the parameters are below the Minimum Acceptable grade. In this case, the final PQA line becomes:
"All Measurements within range".
MicroPDF417
The Full Report from a typical scan looks like the following (line numbers have been added in curly brackets):
{1} This is a typical Micro PDF417 symbol {2} >>> PQA from HHP <<<
{3} MICROPDF: 15 rows x 3 cols, 24 data & 21 chks {4} X roughly = 0.015"
{5} [A] < Row Height = 1.8 X
{6} [A] < Data Safety Margin = 100% (0 Erasures & 0 Errors)
{7} [A] < Edge Accuracy = 70%
{8} [A] < Print Growth = +4% of X
where:
{1} is the Encoded Message.
{2} is the Banner heading.
{3} identifies the Symbology, MICROPDF (or one of its derivatives: COMPOS-
{4} presents an approximate
Note: The reported
{5} lists the average Row Height, assigning the grades as:
1 - 8