2D PQA Reporting

2D PQA Reporting

Full Report

HHP's 2D PQA reporting can be enabled in two different modes: Full Report or Screening.

If you are using Quick*View, you can enable Full Report, a listing of all of a sym- bol's identifying information, measurements, and corresponding grades, by typ- ing the following menu command:

2D_PQA1

or by scanning the following bar code:

Full Report

Note: With the IT4600/4800/4X80, the PQA report is sent out as a second data/ beep sequence after the bar code data. The report has its own HHP code ID of >(0X3E) so it can be uniquely identified.

Screening Report

Screening is a grade-based mode that allows display of a limited list of identify- ing information, as well as only those measurements that are below Minimum Acceptable Grade (MAG) level. With the IT4600/4800/4X80, if all of the param- eters are met in the screening mode, only the bar code data will be output with a beep. If one or more of the measured parameters fail to meet the MAG, the PQA message is also sent with a beep.

Note: With the IT4410/4710, screening mode outputs are also accompanied by a single beep if all parameters are okay or a triple beep if one or more of the measured parameters fail to meet the MAG.

If you are using Quick*View, you can enable Screening by typing the following menu commands:

2D_PQA2

when A is the Minimum Acceptable Grade

2D_PQA3

when B is the Minimum Acceptable Grade

2D_PQA4

when C is the Minimum Acceptable Grade

2D_PQA5

when D is the Minimum Acceptable Grade

1 - 3

Page 7
Image 7