where:

{5} [A] < Row Height = 3.1 X

{6} [A] < Useful Row Height = 2.5 X (82% Row)

{7} [A] < Data Safety Margin = 100% (0 Erasures & 0 Errors)

{8} [B] < Edge Accuracy = 59%

{9} [C] < Print Growth = -43% of X

where:

{1} is always the Encoded Message, the usual data output. In this case "This is a representative PDF417 symbol".

{2} is a standard Banner heading that marks the start of the PQA portion of the output.

{3} identifies the Symbology, PDF417 (or its derivative COMPOSITE-C), and lists other characteristics of this symbol: the height and width of the data field, the numbers of data and check characters, and the corresponding Error Correction Level.

{4} presents an approximate X-dimension, presuming normal viewing dis- tance.

In the Screening PQA modes, the Symbology Identification from Line {3} is com- bined with the approximate X-dimension from Line {4}.

Note: The reported X-dimension is approximate and based upon use of the IT4410LR at 4.7 in (12 cm) (see "Reading Techniques" on page 1-1). If you use different image engines, the X-dimension will vary. If you hold the reader closer than 4.7 in (12 cm), it will have the effect of reporting a larger than true X-dimension. Conversely, if you hold the reader farther away than 4.7 in (12 cm), it will have the effect of reporting a smaller than true X-dimension. Please contact HHP Application Support for additional information. Refer to Chapter 3 for contact information.

{5} lists the average Row Height, assigning the grades as:

Aif Row Height >= 2.5 X F otherwise

In Screening modes, this parameter is reported as "Rows are Too Short (2.2X)" when that is the case.

{6} lists the Useful Row Height, which is the measured Row Height times the codeword yield (listed in parentheses), the percentage of symbol characters scanned that actually decode. The grade is assigned as:

Aif Useful Height >= 2.0 X, else

Bif Useful Height >= 1.6 X, else

Cif Useful Height >= 1.3 X, else