Maintenance And
Servicing
Procedures not specifically explained in this manual must be performed only by a qualified technician.
TIMING BELT REPLACEMENT:
1.Turn off machine, unplug and remove the key.
2.Remove guards and guides. Turn unit on it’s side or upside down on a suitable, clean work surface.
To prevent serious injury
from accidental operation:
Turn the Power Switch of the Shaper/Router to its “OFF” position and unplug the tool from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
To prevent serious injury from Shaper/Router failure:
Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
Slide | Remove | Loosen | |
Bottom | |||
Screws | Screws | ||
Cover Plate | |||
(22) | (22) | ||
(39) off | |||
|
|
Figure 26
3.Loosen and remove two of the four Screws (22) on the Bottom Cover Plate (39) and slide the Plate off of the unit.
Cleaning, Maintenance, and
Lubrication
1.BEFORE EACH USE, inspect the general condition of the tool. Check for loose hardware, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, and any other condition that may affect its safe operation.
2.After Use, wipe external surfaces of the tool with a clean cloth.
3.WARNING! If the supply cord of this power tool is damaged, it must be replaced only by a qualified service technician.
Screw
(31)
Belt Guard (33)
Figure 27
4.Unthread the Screw (31) holding the Belt Guard (33) in place and remove the Belt Guard.
|
| REV 10e |
Page 20 | For technical questions, please call | SKU 32650 |