Pressure Washer | 1. Cord not connected. | 1. | Check that cord is plugged in. | |
will not start | 2. | No power at outlet. | 2. | Check power at outlet. If outlet is unpowered, |
|
|
|
| turn off tool and check circuit breaker. If |
|
|
|
| breaker is tripped, make sure circuit is right |
|
|
|
| capacity for tool and circuit has no other loads. |
| 3. | GFCI circuit breaker tripped. | 3. | Press reset button on GFCI unit on cord. |
| 4. | Internal damage or wear. (Carbon | 4. | Have a qualified technician service tool. |
|
| brushes or switch, for example.) |
|
|
Pressure Washer | 1. GFCI circuit breaker tripped. | 1. | Press reset button on GFCI unit on cord. | |
Stops suddenly | 2. Water leaking from housing. | 2. | SHOCK HAZARD! IMMEDIATELY | |
|
|
|
| discontinue use. Have the unit repaired by |
|
|
|
| a qualified technician before further use. |
Output pressure | 1. Not enough water supply. | 1. | Check water supply hose for kinks, leaks, | |
varies |
|
|
| or blockage. Open faucet all the way. |
| 2. | Air in water supply. | 2. | Check that all connections are tight. |
| 3. | Water Inlet Filter is clogged. | 3. | Remove Filter and clean. |
| 4. | Extension Nozzle not | 4. | Pressure is created by the Nozzle, not the |
|
| attached to Spray Gun. |
| Spray Gun. Attach Extension Nozzle to unit. |
| 5. | Nozzle is clogged. | 5. | Remove Nozzle and clean. |
| 6. | Nozzle has mineral build up. | 6. | Remove Nozzle and clean with vinegar. |
| 7. | Garden hose is too long. | 7. | Recommended garden hose length is |
|
|
|
| 20 to 50 feet, or 30 feet if using well |
|
|
|
| water. Shorten the length of the garden |
|
|
|
| hose if needed to increase pressure. |
| 8. | Internal valves or seals may | 8. | Have a qualified technician service tool. |
|
| be worn or sticking. |
|
|
Trigger does | Safety lock is still engaged. | Press in on the release button on the bottom of | ||
not depress |
|
| the Spray Gun Handle to release the Safety Lock. | |
Detergent will | Incorrect detergent type. | Check that the detergent is the recommended | ||
not dispense |
|
| type of detergent. Clean out dispenser and | |
|
|
| replace with correct type if needed. | |
Performance | Clogged with mineral deposits. | Clean unit with a | ||
decreases over time |
|
| as vinegar or other aqueous acidic cleaner. |
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.