Lubrication:
Before and after each use of the
Step 1. Put two or three drops of lubricant on the NEEDLE (#24), in front of the TRIGGER (#14). Tip the gun backward and allow the lubricant to drip into the front of the GUN HOUSING (#13).
Step 2. Put two or three drops of lubricant on the VOLUME ADJUSTING SCREW (#12). Tip the gun sideways and allow the lubricant to drip into the SPRAYER HOUSING.
Step 3. Put two or three drops of lubricant on the FAN ADJUSTING SCREW (#28). Tip the gun forward and allow the lubricant to drip into the back of the HOUSING (#13).
Step 4. Put one drop of lubricant on the inside of the TRIGGER SCREW (#15). Work the TRIGGER (#14) to allow the lubricant to coat the parts.
Figure 6 -- Lubricating the Touch-Up Gun
SKU 00086 | For technical questions, please call | Page 10 |