Venting15

Venting15

Fig.27

#4 Installing into an existing

chimney (US only)

This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable you may want to install a liner as in method #7.

Fig.28

#5 Installing into an existing fireplace chimney (US only)

This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure.

The damper area must be sealed with a steel plate or fiberglass. A cap should be installed on the chimney to keep out rain. If the chimney condition is questionable you may want to install a liner all the way to the top as in Method #6.