Harman Stove Company 2 Venting16, #6 Installing into an existing fireplace chimney US and Canada

Models: 2

1 29
Download 29 pages 46.61 Kb
Page 16
Image 16
Venting16

Venting16

Fig.29

Fig.30

#6 Installing into an existing fireplace

chimney (US and Canada)

This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure.

In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney.

In this method a cap should also be installed on the chimney to keep out rain. Be sure to use ap- proved pellet vent pipe fittings. Seal pipe joints with silicone in addition to the sealing system used by the manufacturer. Pipe size should be increased to 4" using this method.

#7 Installing into an existing chimney (US and Canada)

This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure.

In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney. The pipe or liner inside the chimney should be 4"diameter.

In this method a cap should also be installed on the chimney to keep out rain. One disadvantage of this method is that it is harder to clean the vent pipe, therefore, there is a tendancy not to do it as often as needed.