Accentra Motor & Component Locations
Outside Air Inlet
Auger Motor
Low Draft
Pressure
Switch
Combustion Motor
Distribution Blower | 3" Flue Pipe Connector |
ESP Probe |
Accentra Pellet Stove Safety Devices
The Combustion Motor Fuse is a thermal overload
The Control Board/ESP combination is responsible for all high limit safety control. There are 2 high limits, one normal operation high limit and one backup high limit. The control has an automatic diagnostic circuit that continuously monitors the ESP and Room Sensor for faults. If a fault should occur, the control sends a status alert and at the same time the unit goes down to minimum feed/minimum burn as a safety condition.
The Low Draft Pressure Switch is a differential pres- sure switch that senses the pressure between the firebox and the room. If the pressure becomes too low for proper combustion, the switch opens, turning off the feeder motor and the igniter element. This switch is connected into the AC (high voltage) wires; therefore, the control may show the feeder motor and igniter lights "on" but they are not.