Installation
TYPICAL BOILER HOT WATER PIPING SHOWING AIR REMOVAL SYSTEM, PROVISIONS FOR THE EXPANSION OF WATER AND THE AUTOMATIC COLD WATER SUPPLY. ALSO SHOWN IS THE AUTOMATIC MIXING VALVE.THIS COULD ALSO BE DONE BY (2) CLOSELY SPACED TEE'S.THE PROPER PIPING FOR THE INTENDED USE WILL BE DETERMINED BY THE INSTALLING CERTIFIED PLUMBER OR HVAC CONTRACTOR.
NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.
UNION
AIR VENT
AIR SCOOP
SYSTEM SUPPLY
* TEMPERATURE/PRESSURE
GAUGE
* AQUASTAT WELL
* PRESSURE
RELIEF VALVE
EXPANSION TANK
(DIAPHRAGM TYPE)
PIPE TO WITHIN 6" OF THE
FLOOR OR A FLOOR DRAIN
UNION |
| SENSING BULB | ||
|
|
|
|
|
|
|
|
|
|
** THERMOMETER
SYSTEM SUPPLY
AUTOMATIC
MIXING VALVE
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| COLD WATER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SUPPLY 1/2" |
|
| PRESSURE REDUCING VALVE (PRV) | CHECK VALVE (OR BACKFLOW | ||||||||||||
|
| ||||||||||||||
|
| OR COMBINATION PRV AND | PREVENTER IF REQUIRED) | ||||||||||||
|
| RELIEF VALVE |
|
|
** THERMOMETER
SYSTEM RETURN | |
|
* ITEMS SUPPLIED
** OPTIONAL
* BOILER DRAIN, 1/2" NPT MALE X
3/4" HOSE MALE (NOT SHOWN)
NOTE: Cold return water temperature (Sustained temperatures below 140 degrees Fahrenheit) will lead to condensation in the firebox. This moisture can lead to creosote formation. To help minimize moisture and creosote, it is strongly recommended that some form of temperature balance is incorporated into the return water system.
NOTICE: When installing with the atmospheric conversion: All of the pressurized system components shown are not nec- essary. Air vents or bleeders will need to be removed from the plumbing system to prevent air from entering the lines. Control Dipswitch #6 will need to be turned “ON”.
18