4" SQUARE JUNCTION BOX

 

 

120 VAC power (by installer)

 

 

 

 

3/8"FLEX CONDUIT

 

 

 

 

 

 

 

from control board

“105 Series” PELLET BOILER

UPS BACKUP FOR COMBUSTION MOTOR

( UNINTERUPTED POWER SUPPLY / BATTERY BACK-UP )

3/8"FLEX CONDUIT

to combustion motor

BLACK

WHITE

WHITE

GREEN/YELLOW

GREEN

WHITE

RED

BROWN

WHITE

GREEN

WHITE

WHITE

DARK BLUE

1/2" CONDUIT

RED

BLACK

WHITE

RED

RED

GREEN

RED

RED

 

GREEN

Relay enclosure box -

GRAINGER # 1EGH7

 

 

 

 

 

 

 

 

 

 

 

If using a standard UPS, it should

 

 

 

 

 

 

 

 

 

 

 

be rated at 650 or higher to

 

 

 

 

 

 

 

 

 

 

 

ensure that the combustion motor

 

 

 

 

 

 

 

 

 

 

 

operates until the fire is out.

 

 

 

 

 

 

 

 

 

 

 

( approximately 20 minutes needed )

 

 

 

 

 

 

 

 

 

 

 

 

CORD CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

16-3 AWG

 

 

 

 

 

 

 

 

 

 

 

 

PVC CORD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER TO THE UPS / Plug UPS into here.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When current is present, will keep UPS in

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

Ready mode.

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

FEMALE

 

 

 

 

 

 

 

WHITE

 

 

WHITE

 

 

 

 

 

8

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These cord tails can be made from an inexpensive 16/3 extension cord.

 

 

4

 

3

 

 

 

 

 

 

 

Make sure that the MALE end is long enough to reach the

 

 

 

 

 

 

 

 

 

 

receptacle on the UPS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

1

 

 

 

 

 

 

WHITE

 

 

 

 

MALE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

POWER FROM THE UPS / This plugs

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

into the UPS. When power fails, UPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

will supply current to the relay.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-3 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVC CORD

Power Failure Backup Supply

DPDT RELAY flange mtd. -

 

GRAINGER # 2XCO2

CORD CONNECTOR

 

43

Page 43
Image 43
Harman Stove Company PB 105 manual Power Failure Backup Supply