Harman Stove Company XL owner manual Installation, Use Only Approved Venting

Models: XL

1 34
Download 34 pages 5.21 Kb
Page 18
Image 18
18 Installation

18 Installation

Only For Qualified Installers

 

 

 

 

 

Venting

Preliminary steps to prepare for the installation of the ShadowLight XL Fireplace Insert

Remove the chimney cap if one exists so that the flue may be cleaned and the venting installed.

Remove any existing hearth accessories such as glass doors, spark screens, andirons, and grates.

Clean the chimney thoroughly to remove ash, soot, and any obstructions, and then clean ash, soot, dust, and debris from the fireplace.

The damper must be locked open to allow the 3" venting to pass through. If it is necessary to modify the damper area to allow passage of the venting, the modifications should be allowed under local codes. Confirm any planned changes with local building officials.

Use Only Approved Venting

Observe local codes when venting the ShadowLight XL. If no local codes exist, follow ANSI Z21.88-2002 installation code.

Do not connect the venting to the flue of a chimney that serves a separate solid-fuel burning appliance.

The venting manufacturer's installation instructions must be followed exactly.

The most efficient venting systems are those that have a minimum number of bends and minimal horizontal runs.

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

Exhaust restrictor plates must be installed depending on type of gas and chimney height. See page 20 to determine restrictor.

“Warning: Failure to position parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.”

Page 18
Image 18
Harman Stove Company XL owner manual Installation, Use Only Approved Venting