Harman Stove Company XL owner manual Ratings Natural Propane

Models: XL

1 34
Download 34 pages 5.21 Kb
Page 7
Image 7

Specifications 7

Air Intake

Vent

On-Off

Thermostat

Switch

On-Off

Thermostat

Switch

Connector

 

 

Leveling Bolt

 

 

 

RATINGS

NATURAL

PROPANE

Input Rating (Btu/hr)(0-2,000 ft)(0-610m)

35,000 BTU

35,000 BTU

Input Rating(Btu/hr)(2000-4500ft)(610-1375m)

34,000 BTU

34,500 BTU

Min. Input Rating (Btu/hr)

21,600 BTU

20,900 BTU

Orifices (DMS)(0-2000 ft)(0-610m)

31

 

50

Orifices (DMS)(2000-4500ft)(610-1375m)

33

 

51

Manifold Pressure (in w.c./kPa)

3.5

/ .87

10.0 / 2.49

Minimum Manifold Pressure (in w.c./kPa)

1.3

/ .32

3.6 / 0.9

Minimum Inlet Pressure (in w.c./kPa)

5.0

/ 1.25

11.0 / 2.74

Maximum Output (BTU/hr)(0 to 4,500 ft.)(0 to 1,375 m)(Blower off) 27,600

28,600

Page 7