Harman Stove Company XL owner manual Is Pilot lit, Light pilot, Replace Thermopile, Replace valve

Models: XL

1 34
Download 34 pages 5.21 Kb
Page 33
Image 33
Is Pilot lit

Trouble Shooting 33

Main Burner will not light (with valve in “on” position)

Is Pilot lit

no

Yes

Light pilot

Check Thermopile voltage at terminals marked

TP on valve. Should be too low approximately 200 mv

with switch “on” and approximately 400 mv with switch “off”.

Replace Thermopile

OK

Check switch, wires, and

bad

 

wiring connectors.

 

OK

Replace valve

Correct problem

Page 33
Image 33
Harman Stove Company XL Is Pilot lit, Light pilot, Replace Thermopile, Replace valve, Trouble Shooting, wiring connectors