TROUBLESHOOTING

WARNING

To avoid any injury or damage, the booster heater must only be serviced by qualified personnel.

WARNING

To avoid any injury or damage to the booster heater turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance.

SYMPTOM

PROBABLE CAUSE

CORRECTIVE ACTION

 

 

 

High temperature limit trips.

Temperature limit set too low.

If booster heater is not overheating,

 

 

replace High Limit Safety Switch.

 

 

 

 

Thermostat set too high.

Adjust or recalibrate (page 27) to proper

 

 

temperature.

 

 

 

 

Incoming water temperature

Incoming water temperature should

 

too high causing nuisance

not be higher than 160°F (71°C).

 

tripping of high temperature

 

 

limit switch.

 

 

 

 

Chattering contactor or low

Loose connections or wire

Tighten all connections and check crimps.

water cutoff circuit board.

connection has insulation

 

 

under crimp.

 

 

 

 

 

Low voltage.

Check control circuit voltage or secondary

 

voltage with transformer.

 

 

 

 

 

 

Probe may be fouled.

Bypass probe by removing wire from low

 

water cutoff probe and grounding to tank.

 

 

 

 

Clean or replace probe if chattering stops.

 

 

 

 

Contactor(s) may be bad.

Test contactor coils. Replace contactor(s)

 

 

if bad.

 

 

 

33

Form No. EBOOSTERM-0406

Page 35
Image 35
Hatco IMPERIAL S manual Troubleshooting