Hayes Microcomputer Products ASLH306 manual GPRS operation

Models: ASLH306

1 29
Download 29 pages 4.07 Kb
Page 16
Image 16

1

CONNECT

Connection.

2

RING

Ringing signal detected.

3

NO CARRIER

Carrier lost or never present.

4

ERROR

Invalid Command.

6

NO DIAL TONE

No dial tone detected.

7

BUSY

Busy signal detected.

8

NO ANSWER

No answer from remote modem.

GPRS operation

The three main commands used to set up a GPRS call with the Delta Plus MOBILE II GSM/GPRS modem in listening mode are as follows:

AT+Gn, where n = 0 to 9

AT+G0 - turns off GPRS mode

AT+G1-9 turns on GPRS mode and auto connects using context 1-9 then listens for a port 23 connection.

If AT+Gn is on ( ie n = 1-9 ) then it will restart if the connection fails, also at power up. To set contexts (n = 1-9) in the following two commands:

AT+CDGCONT = n,”IP”,"Enter access point name (APN) address here"

.

AT*ENAD = n,"GPRS","username","password",1,0

To escape from TCP/IP listening mode when a session is not connected issue a Ctrl C.

This can take several minutes to “detach” from the network and will set AT+G0 until +G is changed or a reset or a power cycle is invoked. This will set the modem back into auto mode.

Firmware version 2.10 and above:

Additional GPRS watchdogs have been added to the modem in order to negate network fail conditions, these ensure that the unit continually re-tries to connect in GPRS mode if a call failure is detected.

Timeouts:

Typically these are –

Online GPRS inactivity timeout of 4m 16s (256 seconds) - covers failure mid session

User exit from GPRS mode (Ctrl C) times out & GPRS restarts after 1m 42 secs unless the AT+G command is used.

Fail safe timeout restarts every 3h 37.6 minutes if unit is offline. Covers random GPRS network failures!

Lack of Signal/Signal Quality (SQ) timeout is 45 minutes.