Healthrider HRCCEL49011 manual Maintenance And Troubleshooting, Battery Replacement

Models: HRCCEL49011

1 24
Download 24 pages 5.75 Kb
Page 20
Image 20
MAINTENANCE AND TROUBLESHOOTING

MAINTENANCE AND TROUBLESHOOTING

Inspect and tighten all parts of the elliptical crosstrainer regularly. Replace any worn parts immediately.

To clean the elliptical crosstrainer, use a damp cloth

and a small amount of mild dish soap.Important:

Keep liquids away from the console and keep the console out of direct sunlight. During storage, remove the batteries from the console.

BATTERY REPLACEMENT

If the console display becomes dim, the batteries should be replaced. Refer to assembly step 5 on page 6 for replacement instructions.

HANDGRIP PULSE SENSOR TROUBLESHOOTING

Avoid moving your hands while using the handgrip pulse sensor; excessive movement may interfere with heart rate readings. Do not hold the metal con- tacts too tightly.

For the most accurate heart rate reading, hold the metal contacts for about 15 seconds.

For optimal performance of the handgrip pulse sen- sor, clean the metal contacts with a soft cloth—do not use alcohol, abrasives, or chemicals.

Next, remove the four Screws (51) from the right Pedal Disc (15), and slide the Pedal Disc off. Remove all Screws (52, 64) from the Right Side Shield (4) and the two Screws (77) from beneath the Pedal Disc, and remove the Right Side Shield. Remove all Screws

(52)from the Left Side Shield (3) and remove the Left Side Shield.

Next, refer to the drawing below and locate the Reed Switch (53). Loosen, but do not remove, the indicated M4 x 16mm Self-tapping Screw (52). Slide the Reed Switch slightly toward or away from the Magnet (58) on the flywheel. Retighten the Screw. Turn the left Pedal Disc (15) for a moment. Repeat until the console dis- plays correct feedback. When the Reed Switch is cor- rectly adjusted, reattach the Side Shields (3, 4), the right Pedal Disc (15), and the Pedal Springs (11).

58

53

15

52

HOW TO ADJUST THE REED SWITCH

If the console does not display correct feedback, the reed switch should be adjusted. To do this, you must remove the Pedal Springs (11), the right Pedal Disc (15), and the Side Shields (3, 4). Refer to step 9 on page 8 and remove the Pedal Springs.

 

 

15

64

 

4

11

3

 

 

 

 

 

 

 

52

 

 

51

 

 

 

77

 

 

 

11

64

 

 

 

 

 

 

51

 

 

77

52

 

 

51

 

 

64

 

 

 

HOW TO ADJUST THE DRIVE BELT

 

If you can feel

 

 

the pedals slip

 

 

while you are

 

 

pedaling, even

 

 

when the

 

 

resistance is

 

 

adjusted to

68

 

the highest

 

 

 

level, the

 

 

Drive Belt (19)

62

 

may need to

19

 

be adjusted.

 

 

To adjust the

 

 

Drive Belt, you must first remove both side shields. Refer to HOW TO ADJUST THE REED SWITCH at

the left and remove the side shields.

Next, loosen the M8 x 22mm Flat Head Screw (68)

and turn the M10 x 70mm Bolt (62) until the Drive Belt

(19)is tight. When the Drive Belt is tight, tighten the Flat Head Screw. Reattach the side shields.

20

Page 20
Image 20
Healthrider HRCCEL49011 manual Maintenance And Troubleshooting, Battery Replacement, Handgrip Pulse Sensor Troubleshooting