3.SYMPTOM: THE WALKING BELT SLOWS WHEN WALKED ON

a.Use only a UL-listed surge protector, rated at 15 amps, with a 14-gauge cord of five feet or less in length.

b.If the walking belt still slows when walked on, please call our Customer Service Department, toll-free.

4. SYMPTOM: THE WALKING BELT IS OFF-CENTER WHEN WALKED ON

a. If the walking belt has shifted to the left, first remove the key and

UNPLUG THE POWER CORD. Using the 3/16” end of the allen wrench, turn the left rear roller adjustment bolt clockwise 1/4 of a

turn. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt has shifted to the right, first remove the key

and UNPLUG THE POWER CORD. Using the 3/16” end of the allen wrench, turn the left rear roller adjustment bolt counter-

clockwise 1/4 of a turn. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

5. SYMPTOM: THE TREADMILL SITS UNEVENLY ON THE FLOOR

a

b

a. Make sure that the two base pads and the stabilizer pad are attached to the treadmill (see assembly steps 1 and 6 on pages 5 and 6).