2700-I WOOD INSERT (ACT)

R

Factory built zero clearance fireplace

(usa installations only)

The Quadra-Fire 2700-I Insert is listed to UL 1482 Standard and is approved for installation into listed factory-built zero clearance fireplaces listed to UL 127 conforming to the follow- ing specifications and instructions:

The original factory-built clearance fireplace chimney cap must be re-installed after installing the approved chim- ney liner meeting type H.T. requirements (2100°F) per UL 1777. The air flow of the factory-built zero-clearance fire- place system must not be altered. The flue liner top support attachment must not reduce the air flow for the existing air- cooled chimney system.

NOTE: Refer to chimney liner manufacturer for recom- mendations on supporting the liner.

 

Inches

Millimeters

Minimum Width of Cavity Opening

28

711

Minimum Height

18-7/8

479

Minimum Depth from Front to Rear

17

432

The following modifications of factory-built fireplaces are permissible: 1) removal of damper; 2) removal of smoke shelf or baffle; 3) removal of ember catches; 4) removal of fire grate; 5) removal of viewing screen/curtain; and, 6) removal of doors.

NOTE: Installation into fireplaces without a permit will void the listing.

The factory-built chimney must be listed per UL 127 and meet the type HT requirements of UL 103. Factory-built fireplace chimneys tested to UL 127-1998, may be at the fireplace manufacturer’s option, tested to the same criteria as UL 103 HT requirements. If the chimney is not listed as meeting HT requirements, or if the factory-built fireplace was tested prior to 1998, a full height listed chimney liner must be installed from the appliance flue collar to the chimney top. The liner must meet type HT requirements (2100ºF) per UL 1777.

The liner must be securely attached to the insert flue collar and the chimney top. To prevent room air passage to the chimney cavity of the fireplace seal the damper area around the chimney liner with high temperature sealant.

The fireplace must not be altered, except that the damper may be removed to accommodate a direct-connect starter pipe or chimney liner, and external trim pieces which do not affect the operation of the fireplace may be removed provid- ing they can be stored on or within the fireplace for reas- sembly if the insert is removed.

Masonry

 

Chimney

 

Flue Tile

Full Listed

Mantel

Liner Option

 

Direct Connect

 

Seal Option

Damper

 

Area

 

 

SEAL DAMpER AREA

Figure 10.1 - Installation Into A Factory-Built Zero-Clearance

Fireplace

The permanent metal warning label provided must be attached to the back of the fireplace, with screws or nails, stating that the fireplace may have been altered to accom- modate the insert, and must be returned to original condition for use as a conventional fireplace.

If the hearth extension is lower than the fireplace opening, the portion of the insert extending onto the hearth must be sup- ported. Manufacturer designed adjustable support kit can be ordered from your dealer. See page 15.

Final approval of this installation type is contingent upon the authority having jurisdiction.

WARNING

Fire Risk.

When lining air-cooled factory-built chimneys:.

Run chimney liner approved to UL 1777 Type HT requirements (2100 degrees F)

Re-install original factory built chimney cap

ONLY

DO NOT block cooling air openings in chimney

Blocking cooling air will overheat the chimney