R
2700-I WOOD INSERT (ACT)
INSTALLATION IN CANADA
MASONRY and HEAT-CIRCULATING
(INSTALLATIONS INTO
PROHIBITED IN CANADA)
Whether installed in a masonry or
•Do not remove bricks or mortar from fireplace to accommodate insert.
•To prevent room air passage to the chimney cavity of the fireplace seal the damper area around the chimney liner with high temperature sealant.
•The permanent metal warning label provided must be affixed to the back of the fireplace with screws or nails to the fireplace, in a location readily visible should the fireplace insert by removed, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a con- ventional fireplace
NOTE:
In Canada when using a
BUILT CHIMNEYS.
Leveling LEGS
1.Remove the 2 screws already installed on each leg.
2.Move legs to the desired height.
3.
Removes |
screw |
Figure 11.1
DOOR HANDLE ASSEMBLY
1.Install washer on door handle shaft.
2.Slide door handle through door.
3.Install second washer(s) as shown.
4.Install key in groove.
5.Align groove in latch cam with key; slide latch cam over shaft.
6.Install locknut.
7.Install spring handle turning
| Door Cross Section |
Latch Cam | (example) |
Locknut |
|
| Spring |
| Handle |
| Door Handle |
| Spacing |
| Washers |
| Square Key |
Figure 11.2
CAUTION
•Do NOT overtighten lock nut.
•Door handle needs to move smoothly.
September 1, 2008 | Page 11 |