![](/images/new-backgrounds/1027720/2772027x1.webp)
2700-I WOOD INSERT (ACT)
R
TOP INSTALLATION INSTRUCTIONS
The top is packaged separately and shipped with the insert. Install on insert after unit is in place and the installation of the panels and trim are complete.
Push the top into place by aligning the pins into the slots and then press down into position.
panel Top
Top
Ashlip
Blower Motor
Figure 14.1
Blower cord may be attached on the left or right side
BLOWER INSTALLATION
Included in Kit: Blower motor and cord
Tools Needed: Phillips head screw driver
The
1.Remove the blower cover from the front of the unit by removing 4 screws, 2 at each end.
2.Remove the ashlip by removing the 2 screws on each side and pulling towards you. The blower housing is assembled and attached to the ashlip and will come out as one unit.
3.Remove the 4 nuts from the housing and attach the blower using the same 4 nuts. See circled area in Figure 14.2
4.Connect the white and black wires to blower motor termi- nals. Connect green ground wire to ground terminal.
5.Install strain relief onto power cord. Using a pair of pliers, squeeze strain relief and push through hole.
6.Plug in and test blower operation.
7.
8.Route power cord away from the unit. Do not route power cord cord under or in front of unit.
Figure 14.2
FAN SPEED CONTROL
ADJUSTMENT, IF NECESSARY*
*The fan Speed Control for this unit is adjusted at the factory, and normally does not require further adjustment.
NOTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently, but should not stop.
1.With the unit plugged in, turn the Speed Control Knob to slow. (Full clockwise.)
2.Use a small screw driver to adjust the fan speed by turning the adjustment mechanism through the hole on the side of the Speed Control.
3.Adjust the speed so the fan runs slowly but does not stop. Turn clockwise to slow the fan and counter- clockwise to increase the speed.
Caution
Shock Risk.
•Do NOT remove grounding prong from plug.
•Plug directly into properly grounded 3 prong receptacle.
•Route cord away from appliance.
•Do NOT route cord under or in front of appliance.
Page 14 | September 1, 2008 |