When planning your fireplace location, the chimney construc- tion and necessary clearances must be considered. The fire- place system and chimney components have been tested to provide flexibility in construction. The following figures are the minimum distances from the base of the fireplace.
•Minimum overall straight height is 6 ft 4 in. if the fireplace is freestanding and a minimum of 10 ft from a combustible structure. See Figure 3.2.
•Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney. Refer to Figure 6.1.
|
| ft | m |
• | Minimum heightwith offset/return | 16 | 4.88 |
• | Maximum height | 90 | 27.43 |
|
|
|
|
• | Maximum chimney length between an offset | 20 | 6.1 |
| and return | ||
|
|
| |
• | Maximum distance between chimney | 35 | 10.67 |
| stabilizers | ||
|
|
| |
• | Double offset/return minimum height | 24 | 7.32 |
• | Maximum unsupported chimney length | 6 | 1.83 |
| between the offset and return | ||
|
|
| |
• | Maximum unsupported chimney height above | 35 | 10.67 |
| the fireplace |
|
|
• | Minimum overall straight height if fireplace is | 6.33 | 1.93 |
| freestanding |
|
|
Note: A maximum of two pairs of offsets and returns may be used.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana | 11 |