E. Chimney Requirements

When planning your fireplace location, the chimney construc- tion and necessary clearances must be considered. The fire- place system and chimney components have been tested to provide flexibility in construction. The following figures are the minimum distances from the base of the fireplace.

Minimum overall straight height is 6 ft 4 in. if the fireplace is freestanding and a minimum of 10 ft from a combustible structure. See Figure 3.2.

Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney. Refer to Figure 6.1.

 

 

ft

m

Minimum heightwith offset/return

16

4.88

Maximum height

90

27.43

 

 

 

 

Maximum chimney length between an offset

20

6.1

 

and return

 

 

 

Maximum distance between chimney

35

10.67

 

stabilizers

 

 

 

Double offset/return minimum height

24

7.32

Maximum unsupported chimney length

6

1.83

 

between the offset and return

 

 

 

Maximum unsupported chimney height above

35

10.67

 

the fireplace

 

 

Minimum overall straight height if fireplace is

6.33

1.93

 

freestanding

 

 

Note: A maximum of two pairs of offsets and returns may be used.

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN4039-156 Rev K • 7/11

11

Page 11
Image 11
Hearth and Home Technologies 36, 42 owner manual Chimney Requirements