5Chimney Assembly

A. Chimney Requirements

Vertical distances are measured from the base of the fire- place.

Minimum overall straight height is 6 ft 4 in. if the fireplace is freestanding and a minimum of 10 ft from a combustible structure. See Figure 3.2.

Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney. Refer to Figure 6.1.

 

 

ft

m

Minimum heightwith offset/return

16

4.88

Maximum height

90

27.43

 

 

 

 

Maximum chimney length between an offset

20

6.1

 

and return

 

 

 

Maximum distance between chimney

35

10.67

 

stabilizers

 

 

 

Double offset/return minimum height

24

7.32

Maximum unsupported chimney length

6

1.83

 

between the offset and return

 

 

 

Maximum unsupported chimney height above

35

10.67

 

the fireplace

 

 

Minimum overall straight height if fireplace is

6.33

1.93

 

freestanding

 

 

Note: A maximum of two pairs of offsets and returns may be used.

WARNING

Fire Risk

Must maintain 2 in. (51 mm) air clearance to insulation and other combustible materials.

To determine the chimney components needed to complete your particular installation, follow the steps below:

Determine the total vertical height of the fireplace installation. This dimension is measured from the base of the fireplace assembly to the point where the smoke exits the termination cap.

Subtract the effective height of the fireplace assembly from the overall height of the fireplace installation (measured from the base of the fireplace to the bottom of the termination cap).

Refer to Table 5.1 to determine what components must be selected to complete the fireplace installation.

Determine the number of ceiling firestops, stabilizers, roof flashing, etc. required to complete the fireplace installation.

CAUTION

Do NOT connect this fireplace to a chimney flue servicing another appliance.

Do NOT connect to any air distribution duct or system.

Table 5.1

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

US

 

Canada ONLY

 

 

Chimney Stabilizer

 

 

 

SL11

 

SL4

4-3/4

121

 

 

 

 

 

Ceiling Firestops

 

 

 

FS538

 

FS538

0

0

 

 

 

 

 

FS540

 

FS540

0

0

Offsets/Returns

 

 

 

SL1130

 

SL430

14-1/2

368

Chimney Sections*

 

 

 

SL1106

 

SL406

4-3/4

121

 

 

 

 

 

SL1112

 

SL412

10-3/4

273

SL1118

 

SL418

16-3/4

425

 

 

 

 

 

SL1136

 

SL436

34-3/4

883

SL1148

 

SL448

46-3/4

1187

n/a

 

SLA10

16-3/4

425

* Dimensions reflect effective height.

14 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN4039-156 Rev K 7/11