5Chimney Assembly
A. Chimney Requirements
Vertical distances are measured from the base of the fire- place.
•Minimum overall straight height is 6 ft 4 in. if the fireplace is freestanding and a minimum of 10 ft from a combustible structure. See Figure 3.2.
•Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney. Refer to Figure 6.1.
|
| ft | m |
• | Minimum heightwith offset/return | 16 | 4.88 |
• | Maximum height | 90 | 27.43 |
|
|
|
|
• | Maximum chimney length between an offset | 20 | 6.1 |
| and return | ||
|
|
| |
• | Maximum distance between chimney | 35 | 10.67 |
| stabilizers | ||
|
|
| |
• | Double offset/return minimum height | 24 | 7.32 |
• | Maximum unsupported chimney length | 6 | 1.83 |
| between the offset and return | ||
|
|
| |
• | Maximum unsupported chimney height above | 35 | 10.67 |
| the fireplace |
|
|
• | Minimum overall straight height if fireplace is | 6.33 | 1.93 |
| freestanding |
|
|
Note: A maximum of two pairs of offsets and returns may be used.
WARNING
Fire Risk
•Must maintain 2 in. (51 mm) air clearance to insulation and other combustible materials.
To determine the chimney components needed to complete your particular installation, follow the steps below:
•Determine the total vertical height of the fireplace installation. This dimension is measured from the base of the fireplace assembly to the point where the smoke exits the termination cap.
•Subtract the effective height of the fireplace assembly from the overall height of the fireplace installation (measured from the base of the fireplace to the bottom of the termination cap).
•Refer to Table 5.1 to determine what components must be selected to complete the fireplace installation.
•Determine the number of ceiling firestops, stabilizers, roof flashing, etc. required to complete the fireplace installation.
CAUTION
•Do NOT connect this fireplace to a chimney flue servicing another appliance.
•Do NOT connect to any air distribution duct or system.
Table 5.1
HEIGHT OF CHIMNEY COMPONENTS | in. | mm | ||
US |
| Canada ONLY |
|
|
Chimney Stabilizer |
|
|
| |
SL11 |
| SL4 | 121 | |
|
|
|
|
|
Ceiling Firestops |
|
|
| |
FS538 |
| FS538 | 0 | 0 |
|
|
|
|
|
FS540 |
| FS540 | 0 | 0 |
Offsets/Returns |
|
|
| |
SL1130 |
| SL430 | 368 | |
Chimney Sections* |
|
|
| |
SL1106 |
| SL406 | 121 | |
|
|
|
|
|
SL1112 |
| SL412 | 273 | |
SL1118 |
| SL418 | 425 | |
|
|
|
|
|
SL1136 |
| SL436 | 883 | |
SL1148 |
| SL448 | 1187 | |
n/a |
| SLA10 | 425 |
* Dimensions reflect effective height.
14 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana