CAUTION
Handle glass assembly with care.
When cleaning glass door:
•Avoid striking, scratching or slamming glass.
•Do NOT use abrasive cleaners.
•Use a hard water deposit glass cleaner on white film.
•Do NOT clean glass when it is hot.
WARNING
Fire Risk
•Do not use chimney cleaners or flame colorants in your fireplace.
Will corrode chimney.
WARNING
Asphyxiation Risk
Fire Risk
Annual inspection by qualified technician recommended.
Check:
•Condition of doors, surrounds and fronts
•Condition of glass and glass assembly
•Obstructions of combustion and ventilation air
•Gas connections and fittings (if present)
•Obstructions of termination cap
•Refractory panels
Clean:
•Glass
•Air passageways, grilles
D. Maintenance Task List
Inspect |
| Maintenance Tasks |
Screens | 1 Assess condition of screen and replace as necessary. Screens are required. | |
| 2 | Verify maintenance of proper clearance to combustible household objects. |
|
| |
Glass Doors | 1 Inspect glass panels for cracks. Replace if this condition is present. | |
| 2 | Confirm there is no damage to glass or glass frame. Replace as necessary. |
| 3 | Clean glass using a |
|
| |
Circulation Compartment | 1 Remove any foreign objects. | |
| 2 | Verify unobstructed air circulation. |
|
| |
Firebox | 1 Inspect condition of refractory. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6 | |
|
| mm). |
Chimney | 1 Inspect for blockage or obstruction such as bird nests, leaves, etc. | |
| 2 | Confirm that termination cap remains clear and unobstructed by plants, etc. |
|
|
|
| 3 | Verify that termination cap clearance to subsequent construction (building additions) has been |
|
| maintained. |
| 4 | Inspect for corrosion or separation. |
| 5 | Verify weather stripping, sealing and flashing remain intact. |
| 6 | Inspect for creosote and remove as needed. (See Sections 10 and 11) |
Grate | 1 If grate burns out, it should be replaced only with the grate specified on the rating plate and in | |
|
| the replacement parts list for this fireplace. |
E. Chimney Fire
In the event of a chimney fire:
•Have the chimney and adjacent structure inspected by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of an NFPA 211 Level 2 inspection of the chimney.
•Replace components of the chimney and fireplace as specified by the professionals.
•Ensure all joints are properly engaged and the chimney is properly secured.
A chimney fire can permanently damage your chimney sys- tem. Failure to replace damaged components and make proper repairs creates risk of fire.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana | 31 |