Page 16 7037-135E September 1, 2008
R
4300 Wood Stove Series (ACC)
NOTE: In Canada when using a factory-built chimney it must
be safety listed, Type UL103 HT (2100
o
F) CLASS “A” or
conforming to CAN/ULC-S629M, STANDARD FOR 650oC
FACTORY-BUILT CHIMNEYS.
5Chimney Requirements
Floor
Protector
Chimney
Connector
Insulated " T "
Flashing
ListedTerminationCap
TrimCollar on
Inside Wall Listed Chimney
Storm Collar
WallSupport
Roof Brace (if required)
Thimble
Floor
Protector
Chimney
Connector
Ceiling Support
Listed Chimney
ListedTermination Cap
Storm Collar
Flashing
Figure 16.1 Prefabricated Exterior Chimney Figure 16.2 - Prefabricated Interior Chimney
A. Venting Components
Chimney Connector:
It is also known as ue pipe or stove pipe. The chimney
connector joins the stove to the chimney. It must be a 6 inch
(152mm) minimum diameter 24 gauge mild steel black or
26 gauge blued steel, or an approved air-insulated double
wall venting pipe.
Thimble:
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is inten ded to keep the walls
from igniting. Site constructed thimbles must meet
NFPA 211 Standard s. Prefab ricated must be suitable
for use with selected chimney and meet UL10 Type HT
Standards. Follow instructions provided by the manufacturer
for manufactured thimbles for masonry chimney and
prefabricated chimneys.
Chimney:
The chimney can be new or existing, masonry or prefabricated
and must meet the following minimum requirements specied
in Section 5B.
B. Chimney Systems
Must be a 6 inch (152mm) diameter (ID) high temperature
chimney listed to UL 10 HT (2100oF) or ULC S629M.
Must use components required by the manufacturer for
installation.
Must maintain clearances required by the manufacturer
for installation.
Refer to manufacturers instructions for installation.
Prefabricated Metal Chimney