D. Flue Draft Considerations

Location of the appliance and chimney will affect perfor- mance. As shown in Figure 6.1 on page 6 the chimney should:

Be installed through the warm space enclosed by the building envelope. This helps to produce more draft, especially during lighting and die down of the fire.

Penetrate the highest part of the roof. This minimizes the affects of wind turbulence and down drafts.

Consider the appliance location in order to avoid floor and ceiling attic joists and rafters.

Exterior conditions such as roof line, surrounding trees, prevailing winds and nearby hills can influence stove performance. Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your flue problem.

To be sure that your appliance burns properly, the chimney draft (static pressure) should be approximately -.04 inch water column (W.C.) during a low burn and -.10 inch W.C. during a high burn, measured 6 inches (152mm) above the top of the appliance after one hour of operation at each burn setting.

NOTE: These are guidelines only, and may vary somewhat for individual installations.

E. Venting Systems

The venting system consists of a chimney connector (also known as stove pipe) and a chimney. These get extremely hot during use. Temperatures inside the chimney may exceed 2000°F (1100°C) in the event of a creosote fire. To protect against the possibility of a house fire, the chimney connector and chimney must be properly installed and maintained. An approved thimble must be used when a connection is made through a combustible wall to a chimney.

A chimney support package must be used when a connection is made through the ceiling to a prefabricated chimney. These accessories are absolutely necessary to provide safe clearances to combustible wall and ceiling material. Follow venting manufacturer’s clearances when installing venting system.

F. Tools And Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Reciprocating saw

Framing Material

Pliers

Hi-Temp Caulking Material

Hammer

Gloves

Phillips Head Screwdriver

Framing Square

Flat Blade Screwdriver

Electric Drill & Bits (1/4”)

Plumb Line

Safety Glasses

Level

1/2 in. - 3/4 in. length, #6 or

Tape Measure

#8 self drilling screws (need 3

 

per pipe section connection)

 

 

G. Inspect Appliance & Components and Pre-Use Check List

1.

 

Place the appliance in a location near the final

 

 

installation area and follow the procedures below:

2.

 

Open the appliance and remove all the parts and

 

 

articles packed inside the Component Pack. Inspect

 

 

all the parts and glass for shipping damage. Contact

 

 

your dealer if any irregularities are noticed.

3.

 

All safety warnings have been read and followed.

4.

 

This Owner’s Manual has been read.

5.

 

Floor protection requirements have been met.

6.

 

Venting is properly installed.

7.

 

The proper clearances from the appliance and chim-

 

 

ney to combustible materials have been met.

8.

 

The masonry chimney is inspected by a professional

 

 

and is clean, or the factory built metal chimney is

 

 

installed according to the manufacturer’s instruc-

 

 

tions and clearances.

9.

 

The chimney meets the required minimum height.

10.

 

All labels have been removed from the glass door.

11.

 

Plated surfaces have been wiped clean, if appli-

 

 

cable.

12.

 

A power outlet is available nearby if installing

 

 

optional blower assembly.

WARNING

Asphyxiation Risk.

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any air distributon duct or system.

May allow flue gases to enter the house.

WARNING

Fire Risk.

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

September 1, 2008

7037-135E

Page

Page 7
Image 7
Hearth and Home Technologies 43ST-ACC, 43M-ACC-MBK warranty Wood Stove Series ACC Flue Draft Considerations, Venting Systems

43M-ACC-MBK, 43ST-ACC specifications

Hearth and Home Technologies has long been a leader in the design and manufacturing of high-quality heating appliances, and their models 43ST-ACC and 43M-ACC-MBK are no exception. These gas fireplaces combine aesthetic appeal with innovative technologies aimed at providing efficient heating solutions for residential spaces.

The 43ST-ACC is designed with versatility in mind. It features a traditional style that can seamlessly integrate into a variety of home decors. One of its standout characteristics is the expansive viewing area that allows homeowners to enjoy the mesmerizing flames. The fireplace utilizes advanced ceramic glass technology that enhances the thermal efficiency, ensuring a warm environment without compromising on safety.

On the technical side, the 43ST-ACC is equipped with the IntelliFire ignition system which provides convenient, reliable startup. This system also allows for enhanced safety features, ensuring the unit operates smoothly and safely. The adjustable flame height and heat output settings further allow users to create their desired ambiance while optimizing fuel consumption.

Additionally, the 43M-ACC-MBK model is geared towards those who appreciate a modern, sophisticated design. This model is characterized by its sleek, black finish and clean lines, making it an eye-catching centerpiece in any room. Like the 43ST-ACC, it also boasts an impressive viewing area, but it comes with the added benefit of customizable features, including remote control operation and programmable thermostats.

Both models are designed with efficiency in mind, incorporating technology that maximizes heat distribution throughout the room. Their direct vent operation ensures that combustion gases are exhausted outside, making them a safe choice for indoor spaces. The inclusion of a blower system in both models enhances air circulation, providing an even distribution of warmth throughout the environment.

In conclusion, the Hearth and Home Technologies 43ST-ACC and 43M-ACC-MBK gas fireplaces combine style, functionality, and advanced technology. Whether you are looking for a traditional touch or a modern flair, these models cater to diverse preferences while ensuring efficient heating and safety. With their innovative features and beautiful designs, they truly represent the pinnacle of home heating solutions. Whether settling in for a cozy evening or entertaining guests, these fireplaces are sure to enhance any living space.