EC SERIES INSTALLATION INSTRUCTIONS

1.Using Offsets and Returns

a.To bypass any overhead obstructions, the chimney may be offset using a 15-deg or 30-deg offset/return. Perform the following steps to determine the correct chimney component combination for your particular installation.

b.An offset and return may be attached together or a chimney section(s) may be used between an offset and return.

1)Measure how far the chimney needs to be shifted to enable it to avoid the overhead obstacle. See Figure 7, dimension “A” to determine chimney sections required to achieve the needed shift.

2)After determining the offset dimension, refer to Table 1 and find the “A” dimension closest to but not less than the distance of shift needed for your installation.

3)The “B” dimension that coincides with the “A” dimension represents the required vertical clearance that is needed to complete the offset and return.

4)Read across the chart and find the number of chimney sections required and the model number of those particular chimney parts.

5)Whenever the chimney penetrates a floor/ceiling, a firestop spacer must be installed.

6)The effective height of the fireplace assembly is measured from the base of fireplace to top of starter collar. See Figure 6.

WARNING!

Do not combine offsets to create an offset greater than 30 deg from verti- cal. This may create a fire hazard since the natural draft may be restricted.

￿ Table 1

 

 

Offset Chart*

 

 

 

 

 

15-degree

30-degree

 

 

 

 

 

 

 

A

 

B

A

B

SL306

SL312

SL318

SL324

SL336

SL348

 

1-5/8 in.

 

13-3/8 in.

3-7/8 in.

14-1/2 in.

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

2-7/8 in.

 

17-3/4 in.

6-1/4 in.

18-5/8 in.

1

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

4-1/8 in.

 

22-3/8 in.

8-5/8 in.

22-3/4 in.

2

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

4-1/2 in.

 

23-5/8 in.

9-1/4 in.

23-3/4 in.

-

1

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

5-3/4 in.

 

28-1/4 in.

11-5/8 in.

27-7/8 in.

1

1

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

6 in.

 

29-3/8 in.

12-1/4 in.

29 in.

-

-

1

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

7-1/4 in.

 

34 in.

14-5/8 in.

33 in.

-

2

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

7-3/4 in.

 

36-1/8 in.

15-1/4 in.

34-1/8 in.

-

-

-

1

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

8-3/4 in.

 

39-3/4 in.

17-5/8 in.

38-1/4 in.

1

-

-

1

-

-

 

 

 

 

 

 

 

 

 

 

 

 

10-3/8 in.

45-5/8 in.

20-5/8 in.

43-1/2 in.

-

-

2

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

10-5/8 in.

46-3/4 in.

21-1/4 in.

44-5/8 in.

-

-

-

-

1

-

 

 

 

 

 

 

 

 

 

 

 

 

11-7/8 in.

51-3/8 in.

23-5/8 in.

48-3/8 in.

1

-

-

-

1

-

 

 

 

 

 

 

 

 

 

 

 

 

13-1/2 in.

57-1/4 in.

26-5/8 in.

53-7/8 in.

-

-

-

2

-

-

 

 

 

 

 

 

 

 

 

 

 

 

13-3/4 in.

58-3/8 in.

27-1/4 in.

55-3/4 in.

-

-

-

-

-

1

 

 

 

 

 

 

 

 

 

 

 

 

 

15 in.

 

63 in.

29-5/8 in.

59 in.

1

-

-

-

-

1

 

 

 

 

 

 

 

 

 

 

 

 

16-1/2 in.

68-3/4 in.

32-5/8 in.

64-1/4 in.

-

1

-

-

-

1

 

 

 

 

 

 

 

 

 

 

 

 

 

18 in.

 

74-5/8 in.

35-5/8 in.

69-1/2 in.

-

-

1

-

-

1

 

 

 

 

 

 

 

 

 

 

 

 

19-5/8 in.

80-3/8 in.

38-5/8 in.

74-5/8 in.

-

-

-

1

-

1

 

 

 

 

 

 

 

 

 

 

 

 

20-5/8 in.

84-1/8 in.

41 in.

78-3/4 in.

1

-

-

1

-

1

 

 

 

 

 

 

 

 

 

 

 

 

22-3/4 in.

91-7/8 in.

44-5/8 in.

85 in.

-

-

-

-

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

24 in.

 

96-1/2 in.

47 in.

89-1/8 in.

1

-

-

-

1

1

 

 

 

 

 

 

 

 

 

 

 

 

25-7/8 in.

103-1/2 in.

50-5/8 in.

95-1/2 in.

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

*Proper assembly of air cooled chimney parts result in an overlap at chimney joints of 1¼”. Effective length is built into this chart.

Figure 7 - Chimney Offset/

Return

Example: Your “A” dimension from Figure 7 is 14-1/2 in. Using Table 1 the dimension closest to, but not less than 14-1/2 in. is 14-5/8 in. using a 30-deg offset/return. It is then determined from the table that you would need 33 in. (Dimension “B”) between the offset and return. The chimney components that best fit your application are two SL312s.

08/04

17339 Rev L

13

Page 13
Image 13
Hearth and Home Technologies EC36 manual Using Offsets and Returns, Offset Chart

EC36 specifications

Hearth and Home Technologies EC36 is a well-regarded product in the realm of modern heating solutions, appealing to consumers seeking a combination of efficiency, aesthetics, and advanced technology. Aimed at both form and function, the EC36 is perfectly suited for today’s homes, blending seamlessly into various interior designs while providing exceptional warmth.

One of the defining features of the EC36 is its efficient heating capacity. With a maximum output of 36,000 BTUs, this unit provides considerable heat for areas up to 1,200 square feet. This makes it an ideal choice for medium to large living spaces, ensuring that your home remains cozy during the coldest months. The innovative design of the EC36 enhances heat distribution, allowing for consistent warmth throughout a room.

The technology behind the EC36 is equally impressive. It utilizes advanced burning technology which promotes efficiency and minimizes emissions. The unit is equipped with a sealed combustion system, allowing it to draw outside air for combustion, rather than using the indoor air. This not only improves efficiency but also enhances air quality within the home. The EC36 is engineered to meet or exceed environmental standards, making it a responsible choice for eco-conscious consumers.

Another characteristic worth noting is the customizable aesthetic of the EC36. The unit is available in various finishes, allowing homeowners to select a style that complements their décor. From sleek black to traditional finishes, the EC36 easily integrates into any design scheme. Additionally, the large viewing window provides a beautiful showcase of the flames, creating an inviting atmosphere.

The operation of the EC36 is designed with user convenience in mind. It features an easy-to-use control panel and offers optional remote control capabilities, enabling homeowners to adjust settings from across the room. The reliability of the ignition system further simplifies operation, allowing users to enjoy the warmth without the hassle.

In conclusion, Hearth and Home Technologies EC36 stands out as a robust choice for effective home heating. With its impressive BTU output, advanced burning technology, customizable aesthetics, and user-friendly operation, the EC36 not only meets but exceeds the expectations of modern homeowners seeking comfort, style, and efficiency.