4.WIRING
a.Wall Switch
The installer shall supply a
Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
Note: Optional Accessories Requirements: Wiring for optional accessories should be done now to avoid reconstruction.
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
b.Standing Pilot Ignition
This standing pilot appliance does not require a 110V AC supply to operate. It is suggested that a switched 110V junction box be installed to power the optional remote control and/or fan.
Only heater listed appliances may be connected to a thermostat. Use a thermostat that is compatible with a millivolt gas valve. See Figure 14.
WARNING!
This appliance does NOT require a 110VAC supply for operations. Connecting the appliance/wall switch to a 110V AC supply will cause the appliance to malfunction and destroy the valve and thermopile.
Figure 14 - Standing Pilot Ignition Wiring Diagram